医学
经皮
透视
腰椎
外科
椎间盘切除术
腰椎间盘突出症
放射科
腰椎
作者
Mengran Jin,Longyue Lei,Fengqing Li,Biao Zheng
标识
DOI:10.1016/j.wneu.2020.12.095
摘要
To evaluate the efficacy and safety of robot-assisted percutaneous endoscopic lumbar discectomy (rPELD) using a specially designed orthopaedic robot with an intraoperative computed tomography–equipped suite for treatment of symptomatic lumbar disc herniation and compare rPELD with fluoroscopy-assisted percutaneous endoscopic lumbar discectomy (fPELD). We retrospectively reviewed and compared demographic data, radiologic workups, and patient-reported outcomes of 39 patients treated with rPELD and 78 patients treated with fPELD at our institution between January 2019 and December 2019. Our data showed that a single-shot puncture in the rPELD group was significantly more precise compared with 4.12 ± 1.71 trials in the fPELD group (P < 0.001). There was an overall reduction of fluoroscopy (21.33 ± 3.89 times vs. 33.06 ± 2.92 times, P < 0.001), puncture-channel time (13.34 ± 3.03 minutes vs. 15.03 ± 4.5 minutes, P = 0.038), and total operative time (57.46 ± 7.49 minutes vs. 69.40 ± 12.59 minutes, P < 0.001) using the rPELD technique versus the fPELD technique. However, there were no significant differences in patient-reported outcomes, length of hospital stay, and complication rate between the 2 groups (P > 0.05). Taken together, our data indicate that rPELD provides a precise skin entry point and optimal trajectory for puncture, which increases the success rate of PELD, negating the need for revision surgery. However, further studies are required to confirm the superiority and application of the rPELD technique.
科研通智能强力驱动
Strongly Powered by AbleSci AI