Rapid Switching of a C-Series Linear Accelerator Between Conventional and Ultrahigh-Dose-Rate Research Mode With Beamline Modifications and Output Stabilization

光束线 系列(地层学) 模式(计算机接口) 直线粒子加速器 物理 核物理学 计算机科学 光学 梁(结构) 操作系统 地质学 古生物学
作者
Austin M. Sloop,M. Ramish Ashraf,Mahbubur Rahman,Jacob Sunnerberg,Chad A. Dexter,Linda Thompson,David J. Gladstone,Brian W. Pogue,Petr Brůža,Rongxiao Zhang
出处
期刊:International Journal of Radiation Oncology Biology Physics [Elsevier]
卷期号:119 (4): 1317-1325 被引量:1
标识
DOI:10.1016/j.ijrobp.2024.01.215
摘要

Purpose In this study, a decommissioned C-series linear accelerator (linac) was configured to enable rapid and reliable conversion between the production of conventional electron beams and an Ultrahigh-dose-rate (UHDR) electron beamline to the treatment room isocenter for FLASH radiation therapy. Efforts to tune the beam resulted in a consistent, stable UHDR beamline. Methods and Materials The linac was configured to allow for efficient switching between conventional and modified electron output modes within two minutes. Additions to the air system allow for retraction of the X-ray target from the beamline when the 10MV photon mode is selected. With the carousel set to an empty port, this grants access to the higher current pristine electron beam normally used to produce clinical photon fields. Monitoring signals related to the automatic frequency control (AFC) system allows for tuning of the waveguide while the machine is in a hold state so a stable beam is produced from the initial pulse. A pulse counting system implemented on a FPGA-based controller platform controls the delivery to a desired number of pulses. Beam profiles were measured with Gafchromic film. Pulse-by-pulse dosimetry was measured using a custom electrometer designed around the EdgeTM diode. Results This method reliably produces a stable UHDR electron beam. Open field measurements of the 16cm (FWHM) gaussian beam saw average dose rates of 432Gy/s at treatment isocenter. Pulse overshoots were limited and ramp up was eliminated. Over the last year, there have been no recorded incidents that resulted in machine downtime due to the UHDR conversions. Conclusion Stable 10MeV UHDR beams were generated to produce an average dose rate of 432Gy/s at the treatment room isocenter. With a reliable pulse-counting beam control system, consistent doses can be delivered for FLASH experiments with the ability to accommodate a wide range of field sizes, source-to-surface distances, and other experimental apparatus that may be relevant for future clinical translation.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
大幅提高文件上传限制,最高150M (2024-4-1)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
2秒前
LH发布了新的文献求助10
3秒前
3秒前
醉熏的初柳完成签到,获得积分10
4秒前
4秒前
6秒前
独特的完成签到,获得积分10
7秒前
qiqi完成签到 ,获得积分10
7秒前
Shuang完成签到 ,获得积分10
8秒前
9秒前
10秒前
LZM完成签到,获得积分10
10秒前
独特的发布了新的文献求助10
10秒前
666发布了新的文献求助10
10秒前
yangching完成签到,获得积分10
11秒前
王小头要查文献完成签到,获得积分10
12秒前
13秒前
DAN_完成签到,获得积分10
14秒前
cindy完成签到,获得积分10
14秒前
orixero应助卷卷采纳,获得10
15秒前
LH完成签到,获得积分20
16秒前
传奇3应助拼搏的秋玲采纳,获得10
17秒前
17秒前
20秒前
leolee完成签到 ,获得积分10
20秒前
It6发布了新的文献求助10
22秒前
ghh完成签到,获得积分20
23秒前
keyantong666完成签到,获得积分10
23秒前
猫xuan发布了新的文献求助10
24秒前
25秒前
Jenny关注了科研通微信公众号
27秒前
打打应助GaPb氘壬采纳,获得10
27秒前
30秒前
yjc发布了新的文献求助10
31秒前
小羊完成签到,获得积分10
32秒前
32秒前
33秒前
34秒前
无情的匪完成签到 ,获得积分10
34秒前
可耐的手机完成签到 ,获得积分10
34秒前
高分求助中
Evolution 10000
Sustainability in Tides Chemistry 2800
юрские динозавры восточного забайкалья 800
English Wealden Fossils 700
An Introduction to Geographical and Urban Economics: A Spiky World Book by Charles van Marrewijk, Harry Garretsen, and Steven Brakman 500
Diagnostic immunohistochemistry : theranostic and genomic applications 6th Edition 500
Chen Hansheng: China’s Last Romantic Revolutionary 500
热门求助领域 (近24小时)
化学 医学 生物 材料科学 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 基因 遗传学 催化作用 物理化学 免疫学 量子力学 细胞生物学
热门帖子
关注 科研通微信公众号,转发送积分 3151831
求助须知:如何正确求助?哪些是违规求助? 2803210
关于积分的说明 7852429
捐赠科研通 2460582
什么是DOI,文献DOI怎么找? 1309902
科研通“疑难数据库(出版商)”最低求助积分说明 629061
版权声明 601760