医学
观察研究
临床终点
导管
外周穿刺中心静脉导管
外科
穿孔
人口
前瞻性队列研究
入射(几何)
随机对照试验
内科学
冶金
材料科学
物理
光学
冲孔
环境卫生
作者
Martin Troubil,Giuseppe Capozzoli,Baudolino Mussa,Melinda J. Hodne,Klaus Hoerauf,Kimberly Alsbrooks
出处
期刊:BMJ Open
[BMJ]
日期:2024-09-01
卷期号:14 (9): e081288-e081288
标识
DOI:10.1136/bmjopen-2023-081288
摘要
Objective This study aimed to evaluate the safety and performance of PowerPICC catheters in a real-world setting. Design Prospective, observational, multicentre study. Setting Nine European countries, involving 14 centres. Participants General patient population. Intervention PowerPICC catheter inserted by the clinician as standard of care with routinely collected outcomes followed through device removal or 180 days postinsertion. Primary and secondary outcomes measures Safety and performance outcomes were assessed for PowerPICC, PowerPICC SOLO 2 and PowerGroshong PICC. The primary safety endpoint was the incidence of symptomatic venous thrombosis (VT), and secondary safety endpoints included phlebitis, extravasation, vessel laceration, vessel perforation local infection, accidental dislodgment and catheter-related bloodstream infection (CRBSI). The primary performance endpoint was the percentage of patients whose PowerPICC device remained in place through the completion of therapy. The secondary performance endpoints included catheter patency, placement success in a single attempt and usability. Results The enrolled patients (N=451) received either PowerPICC, PowerPICC SOLO 2 or PowerGroshong PICC catheters. Across all devices, 1.6% of patients developed symptomatic VT, and CRBSI occurred in 1.6% of patients. There were no cases of phlebitis or extravasation and only three cases of vein laceration or vein perforation. The catheters showed high success rates in completing therapy (81.8%), maintaining patency (93.9%) and achieving successful placement in a single attempt (90.4%). Clinicians overwhelmingly agreed that both the guidewire and stylet (93.3% and 94.4%, respectively) were easy or very easy to use. Conclusions This study demonstrates the safety and performance of PowerPICC catheters across diverse settings and patient cohorts in real-world hospital settings across Europe. The findings indicate that these catheters are safe and can be effectively used in the general patient setting and when inserted by a variety of clinicians. The low incidence of complications and high success rates further support the clinical utility of these catheters. Trial registration number NCT04263649 .
科研通智能强力驱动
Strongly Powered by AbleSci AI