摘要
Low-frequency ultrasound (LFU) in the frequency range 30-40 kHz administered using different delivery methods (waterbath and noncontact spray) has shown positive effects on chronic wound healing rates in humans, but the underlying mechanisms are only beginning to be explored. To examine the effects of LFU delivered at 35 kHz on the morphology and migration of human fibroblasts, real-time videography was used to record the rate and character of cultured human fibroblast migration at 8-hour increments for 48 hours in a wound assay model. Cells were treated with 35 kHz LFU or saline only (control). Cellular morphology (cell shape, packing, and apparent length) and migration patterns including orientation were analyzed using time-lapse videography. LFU delivered at a frequency of 35 kHz produced a different pattern of fibroblast migration in vitro (varied orientation versus vertical orientation for untreated cells) and altered cell morphology compared to controls. The observed pattern of migration was more varied and widely distributed across multiple angles versus the predominant parallel orientation of the migrating untreated cells. The potential implications of these findings on collagen placement in the extracellular matrix, which may affect degree of soft tissue scarring, should be further investigated.