霍恩斯菲尔德秤
医学
骨质疏松症
骨矿物
腰椎
核医学
腰椎
双重能量
腰椎
骨密度
椎体
解剖
放射科
计算机断层摄影术
外科
内科学
作者
Mengyang Pu,Bo Zhang,Ying Zhu,Wentao Zhong,Yixin Shen,Peng Zhang
标识
DOI:10.1016/j.wneu.2023.07.146
摘要
To assess the consistency and accuracy of various measurements of the Hounsfield unit (HU) in lumbar vertebrae. The study reviewed lumbar spine computed tomography images of 60 postmenopausal women aged >50 years. A total of 240 vertebrae were measured and analyzed for the variations of HU values in different sections and regions. Investigated the relationship between HU values of the lumbar spine under different measurements and dual-energy X-ray absorptiometry results and the ability to identify patients with osteoporosis. HU values measured in midsagittal (r = 0.763), midcoronal (r = 0.768), and midaxial (r = 0.786) sections exhibited a strong positive correlation with dual-energy X-ray absorptiometry T-scores. HU values measured in midsagittal and midaxial sections of the vertebral body were in good agreement (P > 0.1), but decreased in the midcoronal (P < 0.001). HU values in the middle of the vertebral body were significantly higher than in the near end plate (P < 0.001). HU values varied between L1 and L4 vertebrae, but all had a good ability to identify osteoporosis and did not differ significantly in screening ability (P > 0.05). An averaged HU value in axial multilevel is a comprehensive assessment of vertebral bone density. Using the HU value of the lumbar spine can help identify patients with osteoporosis, and the screening ability does not differ significantly across vertebral segments.
科研通智能强力驱动