Comparison of Ocular Morphological Parameters Related to Lens Position by Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy

医学 超声生物显微镜 眼科 光学相干层析成像 超声波 协议限制 核医学 一致性(知识库) 青光眼 数学 放射科 几何学
作者
Zhiying Yu,Fenglei Wang,Fang Dong,Na Li,Dabo Wang,Ling Wang
出处
期刊:International Journal of Clinical Practice [Wiley]
卷期号:2022: 1-7 被引量:5
标识
DOI:10.1155/2022/7599631
摘要

The objective is to compare parameters related to lens position measured using anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) in patients with senile cataract and perform a consistency analysis.This prospective study included 102 patients (102 eyes) scheduled for simple cataract surgery. Among the total patients, 44 were men, and 58 were women. AS-OCT (sitting) and UBM (lying) were used to measure the anterior chamber depth (ACD) in horizontal and vertical orientations and the iris-lens contact distance (ILCD) and iris-lens angle (ILA) in inferior, superior, nasal, and temporal quadrants. Paired-sample t-test was used to compare ACD, ILCD, and ILA measurements of the two methods, while Pearson's linear correlation and Bland-Altman analyses were used to analyze the correlation and consistency of the two results.The horizontal (2.499 ± 0.464 mm) and vertical (2.531 ± 0.463 mm) ACD measured using AS-OCT and the horizontal (2.556 ± 0.467 mm) and vertical (2.563 ± 0.479 mm) ACD measured using UBM were significantly different (P < 0.001); moreover, the results showed good correlation and agreement. A significant difference was observed between the two methods in terms of ILCD measured in inferior, superior, nasal, and temporal quadrants (P < 0.001), and a significant correlation was found between measurements of both methods (P < 0.001). Approximately 3.92% (4/102), 0.98% (1/102), 3.92% (4/102), and 2.94% (3/102) of points were outside the 95% limits of agreement in the four quadrants, respectively, and the agreement of the results was good. ILA measured using both methods differed in inferior, superior, nasal, and temporal quadrants (P=0.003, 0.011, 0.001, 0.001, respectively), and the correlation was good (P < 0.001). The percentage of points outside the 95% limit was higher in inferior, superior, nasal, and temporal quadrants (4.90% (5/102), 5.88% (6/102), 5.88% (6/102), and 6.86% (7/102)) with poor agreement of the results.The correlation between AS-OCT and UBM in terms of measuring lens position-related parameters was good, but the agreement was unstable. The differences in measurement position (sitting and supine) and/or measurement methods (optics and ultrasound) may lead to variability in results.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
大幅提高文件上传限制,最高150M (2024-4-1)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
Cupid完成签到,获得积分10
刚刚
haofan17完成签到,获得积分10
刚刚
坚强的赛凤完成签到,获得积分10
1秒前
1秒前
大模型应助云宇采纳,获得10
2秒前
Ava应助Kidmuse采纳,获得10
2秒前
huahua发布了新的文献求助10
2秒前
爱上彩色发布了新的文献求助10
2秒前
2秒前
S8发布了新的文献求助10
2秒前
英姑应助kkk采纳,获得10
3秒前
xiaodang完成签到,获得积分10
6秒前
科研通AI2S应助迷你的幻姬采纳,获得10
8秒前
11秒前
11秒前
爱上彩色完成签到,获得积分10
11秒前
zpt发布了新的文献求助10
11秒前
ljs发布了新的文献求助10
12秒前
yyymmma应助等待的士晋采纳,获得10
13秒前
13秒前
充电宝应助ATYS采纳,获得10
13秒前
14秒前
lsy完成签到,获得积分20
14秒前
15秒前
ruby发布了新的文献求助10
15秒前
15秒前
斯文败类应助三点知羽采纳,获得10
15秒前
15秒前
czx发布了新的文献求助10
16秒前
kaiser发布了新的文献求助10
17秒前
飞飞飞完成签到,获得积分10
17秒前
19秒前
云宇发布了新的文献求助10
19秒前
21秒前
21秒前
闪闪绮梅完成签到 ,获得积分10
21秒前
22秒前
23秒前
sjc发布了新的文献求助10
24秒前
25秒前
高分求助中
Sustainability in Tides Chemistry 2800
The Young builders of New china : the visit of the delegation of the WFDY to the Chinese People's Republic 1000
Rechtsphilosophie 1000
Bayesian Models of Cognition:Reverse Engineering the Mind 888
The SAGE Handbook of Qualitative Research 800
Le dégorgement réflexe des Acridiens 800
Defense against predation 800
热门求助领域 (近24小时)
化学 医学 生物 材料科学 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 基因 遗传学 催化作用 物理化学 免疫学 量子力学 细胞生物学
热门帖子
关注 科研通微信公众号,转发送积分 3135113
求助须知:如何正确求助?哪些是违规求助? 2786095
关于积分的说明 7775189
捐赠科研通 2441915
什么是DOI,文献DOI怎么找? 1298256
科研通“疑难数据库(出版商)”最低求助积分说明 625108
版权声明 600839