H. Y. Li,S. J. Li,Q. F. Xie,J. H. Liu,Ruixin Bai,Ran Tao,Xulei Lun,N. Li,X. K. Bo,C. Q. Liu,Lei Han,B. H. Deng
摘要
A 15-point Thomson scattering diagnostic system is developed for ENN's spherical torus experiment XuanLong-50 (EXL-50). A BeamTech laser with 3 J/pulse (1064 nm wavelength) at 50 Hz repetition rate is chosen for measurements during EXL-50 plasma operations. To enable measurements at low density (∼0.5 × 1018 m-3) plasma operations, the opto-mechanical subsystems are carefully designed to maximize the collection and transmission of the scattered light and to minimize the stray light level. In addition, the high bandwidth trans-impedance amplifiers and segmented high speed waveform digitizers allow for the application of muti-pulse averaging to further improve the signal-to-noise ratio. Details of the diagnostic system are described and initial experimental results are presented.