玻璃体后脱离
屈光度
玻璃体切除术
眼科
对比度(视觉)
医学
折射误差
视网膜
视力
视网膜脱离
光学
物理
作者
Justin H. Nguyen,Jeannie Nguyen-Cuu,Jonathan Mamou,Brittany Routledge,Kenneth M.P. Yee,J. Sebag
标识
DOI:10.1016/j.ajo.2020.09.017
摘要
•Axial myopia has increased vitreous echodensity and decreased contrast sensitivity. •PVD further increases vitreous density and degrades contrast sensitivity in myopia. •Limited vitrectomy normalizes contrast sensitivity function in myopic vitreopathy. Purpose Myopic vitreopathy features precocious fibrous vitreous liquefaction and early posterior vitreous detachment (PVD). It is unclear whether visual function is affected by myopic vitreopathy and PVD. This study assessed the relationships among axial length, structural vitreous density, PVD, and visual function. Design Retrospective case-control study. Methods Ultrasonography measurements were made of axial length, logMAR VA, contrast sensitivity function (CSF [Freiburg acuity contrast test]), and quantitative B-scan ultrasonography. Results Seventy-nine subjects (45 men and 34 women; mean age: 49 ± 14 years) were analyzed. Axial lengths ranged from 22 to 29.2 mm (mean: 24.9 ± 1.8 mm; myopic eyes: 26.35 ± 1.35 mm; and nonmyopic eyes: 23.45 ± 0.75 mm; P < .001). With increasing axial length there was greater vitreous echodensity (R: 0.573; P < .01) and degradation in CSF (R: 0.611; P < .01). Subgroup analyses found that myopic eyes (>− 3 diopters) had 37% more vitreous echodensity than nonmyopic eyes (762 ± 198 arbitrary units [AU] vs. 557 ± 171 AU, respectively; P < .001) and that CSF was 53% worse in myopic eyes (3.30 ± 1.24 Weber index [%W]) than in nonmyopic eyes (2.16 ± .59 %W; P < .001). Myopic eyes with PVD had 33% greater vitreous echodensity (815 ± 217 AU; P < .001) and 62% degradation in CSF (3.63 ± 2.99 %W) compared to nonmyopic eyes with PVD (613 ± 159 AU; 2.24 ± 0.69 %W; P < .001, each). Limited vitrectomy was performed in 11 of 40 cases (27.5%), normalizing vitreous echodensity and CSF in each case. Conclusions Axial myopia is associated with increased fibrous vitreous liquefaction and echodensity, as well as profound degradation of CSF. PVD in myopic eyes is associated with even more structural and functional abnormalities, normalized by limited vitrectomy. These findings may explain some common complaints of myopic patients with respect to vision and quality of life. Myopic vitreopathy features precocious fibrous vitreous liquefaction and early posterior vitreous detachment (PVD). It is unclear whether visual function is affected by myopic vitreopathy and PVD. This study assessed the relationships among axial length, structural vitreous density, PVD, and visual function. Retrospective case-control study. Ultrasonography measurements were made of axial length, logMAR VA, contrast sensitivity function (CSF [Freiburg acuity contrast test]), and quantitative B-scan ultrasonography. Seventy-nine subjects (45 men and 34 women; mean age: 49 ± 14 years) were analyzed. Axial lengths ranged from 22 to 29.2 mm (mean: 24.9 ± 1.8 mm; myopic eyes: 26.35 ± 1.35 mm; and nonmyopic eyes: 23.45 ± 0.75 mm; P < .001). With increasing axial length there was greater vitreous echodensity (R: 0.573; P < .01) and degradation in CSF (R: 0.611; P < .01). Subgroup analyses found that myopic eyes (>− 3 diopters) had 37% more vitreous echodensity than nonmyopic eyes (762 ± 198 arbitrary units [AU] vs. 557 ± 171 AU, respectively; P < .001) and that CSF was 53% worse in myopic eyes (3.30 ± 1.24 Weber index [%W]) than in nonmyopic eyes (2.16 ± .59 %W; P < .001). Myopic eyes with PVD had 33% greater vitreous echodensity (815 ± 217 AU; P < .001) and 62% degradation in CSF (3.63 ± 2.99 %W) compared to nonmyopic eyes with PVD (613 ± 159 AU; 2.24 ± 0.69 %W; P < .001, each). Limited vitrectomy was performed in 11 of 40 cases (27.5%), normalizing vitreous echodensity and CSF in each case. Axial myopia is associated with increased fibrous vitreous liquefaction and echodensity, as well as profound degradation of CSF. PVD in myopic eyes is associated with even more structural and functional abnormalities, normalized by limited vitrectomy. These findings may explain some common complaints of myopic patients with respect to vision and quality of life.
科研通智能强力驱动
Strongly Powered by AbleSci AI