医学
外科
内固定
减压
射线照相术
支架
放射科
回顾性队列研究
椎板切除术
经皮
固定(群体遗传学)
脊髓
环境卫生
精神科
人口
作者
Alessandro Cianfoni,Daniela Distefano,P. Scarone,G. Pesce,Vittoria Espeli,Luigi La Barbera,Tomaso Villa,Michael Reinert,Giuseppe Bonaldi,Joshua A Hirsch
出处
期刊:Journal of neurosurgery
[Journal of Neurosurgery Publishing Group]
日期:2020-04-01
卷期号:32 (4): 507-518
被引量:7
标识
DOI:10.3171/2019.9.spine19711
摘要
OBJECTIVE Severe lytic cancerous lesions of the spine are associated with significant morbidity and treatment challenges. Stabilization and restoration of the axial load capability of the vertebral body (VB) are important to prevent or arrest vertebral collapse. Percutaneous stent screw–assisted internal fixation (SAIF), which anchors a VB stent/cement complex with pedicular screws to the posterior vertebral elements, is a minimally invasive, image-guided, 360° internal fixation technique that can be utilized in this patient cohort. The purpose of this study was to assess the feasibility, safety, and stabilization efficacy of VB reconstruction via the SAIF technique in a cohort of patients with extensive lytic vertebral lesions, who were considered to have an unstable or potentially unstable spine according to the Spinal Instability Neoplastic Score (SINS). METHODS This study was a retrospective assessment of a prospectively maintained database of a consecutive series of patients with neoplastic extensive extracompartmental osteolysis (Tomita type 4–6) of the VB treated with the SAIF technique. VB reconstruction was assessed on postprocedure plain radiographs and CT by two independent raters. Technical and clinical complications were recorded. Clinical and imaging follow-ups were assessed. RESULTS Thirty-five patients with extensive osteolytic metastatic lesions of the VB underwent 36 SAIF procedures. SAIF was performed as a stand-alone procedure in 31/36 cases and was associated with posterior surgical fixation in 5/36 (4/5 with decompressive laminectomy). In 1 case an epidural cement leak required surgical decompression. VB reconstruction was categorized as satisfactory (excellent or good rating) by the two raters in 34/36 cases (94.5%) with an interrater reliability of 94.4% (Cohen’s kappa of 0.8). Follow-up, ranging from 1 to 30 months, was available for 30/36 levels. Long-term follow-up (6–30 months, mean 11.5 months) was available for 16/36 levels. Stability during follow-up was noted in 29/30 cases. CONCLUSIONS SAIF provides 360° nonfusion internal fixation that stabilizes the VB in patients with extensive lytic lesions that would otherwise be challenging to treat.
科研通智能强力驱动
Strongly Powered by AbleSci AI