B. Chomet,Djamal Gacemi,O. Lopez,L. Del Balzo,Angela Vasanelli,Yanko Todorov,Benoît Darquié,C. Sirtori
摘要
A continuous-wave Fabry–Pérot quantum cascade laser (QCL) emitting at 8.1 μm operating in the single mode regime has been coherently phase locked to a turn-key low-noise commercial mid-Infrared (mid-IR) optical frequency comb. The stability of the comb used as a reference is transferred to the QCL resulting in an integrated residual phase error of 0.4 rad. The laser linewidth is narrowed by more than two orders of magnitude reaching sub-kHz level at 1 ms observation time, limited by the spectral purity of the mid-IR comb. Our experiment is an important step toward the development of both powerful and metrology-grade QCLs and fully stabilized QCL frequency comb and opens perspectives for precision measurements and frequency metrology in the mid-IR.