摘要

ObjectivesThis study sought to compare the local tissue response and subsequent volume of intimal hyperplasia (IH) that develops throughout the maturation of an arteriovenous fistula created using continuous/interrupted polypropylene with that of a novel, metal-alloy, penetrating anastomotic clip device.Materials and methodsForty-six fistulae were created in 23 sheep under a paired design using the nitinol U-Clip (n = 23) in one hind limb and continuous (n = 20) or interrupted (n = 3) polypropylene suture for the other. Animals were killed at 4 (n = 3), 14 (n = 3), 28 (n = 10), 42 (n = 3), and 180 (n = 4) days. Histological sections were evaluated for quantitative histology and immunohistochemistry.ResultsCompared with continuous polypropylene, U-Clip specimens demonstrated less intima–media area per unit length (IMA/L), proliferating cells, and tissue necrosis at all time points (MANOVA, F = 9.8–24.1, all p ≤ .005; observed power >82%). Specifically, values of IMA/L were reduced by 5% (p = .97), 37% (p = .02), 33% (p < .01), 9% (p = .42), and 14% (p = .22) at the time points of 4, 14, 28, 42, and 180 days respectively. Proliferating cells were reduced by 75% (p < .01), 72% (p = .03), 76% (p = .03), 27% (p = .31), and 60% (p = .01) and tissue necrosis by 67% (p < .01), 58% (p = .02), 40% (p = .33), 21% (p = .43), 77% (p = .11). In a 28-day comparison between U-Clip and interrupted polypropylene the U-Clip group demonstrated a 4% (p = .65) reduction in IMA/L, 74% (p < .01) in proliferating cells and 49% (p < .05) in tissue necrosis.ConclusionsThese results provide evidence of reduced local tissue necrosis, proliferating cells, and IH, favouring arteriovenous fistulae created using the U-Clip anastomotic device over conventional polypropylene suture techniques most evident over the first 4 weeks. This study sought to compare the local tissue response and subsequent volume of intimal hyperplasia (IH) that develops throughout the maturation of an arteriovenous fistula created using continuous/interrupted polypropylene with that of a novel, metal-alloy, penetrating anastomotic clip device. Forty-six fistulae were created in 23 sheep under a paired design using the nitinol U-Clip (n = 23) in one hind limb and continuous (n = 20) or interrupted (n = 3) polypropylene suture for the other. Animals were killed at 4 (n = 3), 14 (n = 3), 28 (n = 10), 42 (n = 3), and 180 (n = 4) days. Histological sections were evaluated for quantitative histology and immunohistochemistry. Compared with continuous polypropylene, U-Clip specimens demonstrated less intima–media area per unit length (IMA/L), proliferating cells, and tissue necrosis at all time points (MANOVA, F = 9.8–24.1, all p ≤ .005; observed power >82%). Specifically, values of IMA/L were reduced by 5% (p = .97), 37% (p = .02), 33% (p < .01), 9% (p = .42), and 14% (p = .22) at the time points of 4, 14, 28, 42, and 180 days respectively. Proliferating cells were reduced by 75% (p < .01), 72% (p = .03), 76% (p = .03), 27% (p = .31), and 60% (p = .01) and tissue necrosis by 67% (p < .01), 58% (p = .02), 40% (p = .33), 21% (p = .43), 77% (p = .11). In a 28-day comparison between U-Clip and interrupted polypropylene the U-Clip group demonstrated a 4% (p = .65) reduction in IMA/L, 74% (p < .01) in proliferating cells and 49% (p < .05) in tissue necrosis. These results provide evidence of reduced local tissue necrosis, proliferating cells, and IH, favouring arteriovenous fistulae created using the U-Clip anastomotic device over conventional polypropylene suture techniques most evident over the first 4 weeks.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
1秒前
7_2U1发布了新的文献求助10
2秒前
2秒前
2秒前
Maple发布了新的文献求助10
3秒前
wonderingria完成签到,获得积分10
3秒前
3秒前
3秒前
李爱国应助吉吉采纳,获得10
3秒前
能干亦玉完成签到,获得积分10
5秒前
5秒前
李爱国应助优雅的夜柳采纳,获得10
5秒前
英吉利25发布了新的文献求助10
5秒前
junkljsun发布了新的文献求助10
6秒前
SY完成签到,获得积分10
6秒前
6秒前
胖蛋蛋蛋完成签到,获得积分10
6秒前
7秒前
ffl完成签到 ,获得积分10
7秒前
7秒前
扶苏发布了新的文献求助10
8秒前
8秒前
8秒前
LLLLLLLj发布了新的文献求助10
8秒前
8秒前
8秒前
搜集达人应助虾仁采纳,获得10
9秒前
所所应助乐观的含蕾采纳,获得10
10秒前
PSCs发布了新的文献求助10
10秒前
10秒前
负责乐安发布了新的文献求助10
10秒前
11秒前
文白完成签到,获得积分10
11秒前
11秒前
噗噗发布了新的文献求助10
11秒前
ycx发布了新的文献求助10
12秒前
Li完成签到,获得积分10
12秒前
大神装发布了新的文献求助10
12秒前
12秒前
sj完成签到,获得积分10
13秒前
高分求助中
The Mother of All Tableaux Order, Equivalence, and Geometry in the Large-scale Structure of Optimality Theory 2400
Ophthalmic Equipment Market by Devices(surgical: vitreorentinal,IOLs,OVDs,contact lens,RGP lens,backflush,diagnostic&monitoring:OCT,actorefractor,keratometer,tonometer,ophthalmoscpe,OVD), End User,Buying Criteria-Global Forecast to2029 2000
Optimal Transport: A Comprehensive Introduction to Modeling, Analysis, Simulation, Applications 800
Official Methods of Analysis of AOAC INTERNATIONAL 600
ACSM’s Guidelines for Exercise Testing and Prescription, 12th edition 588
Treatise on Geochemistry 500
T/CIET 1202-2025 可吸收再生氧化纤维素止血材料 500
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 遗传学 基因 物理化学 催化作用 冶金 细胞生物学 免疫学
热门帖子
关注 科研通微信公众号,转发送积分 3954947
求助须知:如何正确求助?哪些是违规求助? 3501093
关于积分的说明 11101851
捐赠科研通 3231470
什么是DOI,文献DOI怎么找? 1786438
邀请新用户注册赠送积分活动 870058
科研通“疑难数据库(出版商)”最低求助积分说明 801798