Influence of Tibial Component Design Features and Interference Fit on Implant-Bone Micromotion in Total Ankle Replacement: A Finite Element Study

医学 踝关节置换术 植入 骨整合 脚踝 固定(群体遗传学) 胫骨 口腔正畸科 生物医学工程 生物力学 牙科 外科 解剖 环境卫生 人口
作者
Gabriel Clarke,Joshua E. Johnson,César de César Netto,Donald D. Anderson
出处
期刊:Foot & Ankle International [SAGE Publishing]
卷期号:45 (12): 1414-1421 被引量:4
标识
DOI:10.1177/10711007241281294
摘要

Background: Implant survivorship in uncemented total ankle replacement (TAR) is dependent on achieving initial stability. This is because early micromotion between the implant and bone can disrupt the process of osseointegration, leading to poor long-term outcomes. Tibial implant fixation features are designed to resist micromotion, aided by bony sidewall retention and interference fit. The goal of this study was to investigate design-specific factors influencing implant-bone micromotion in TAR tibial components with interference fit. Methods: Three implant designs with fixation features representative of current TAR tibial components (ARC, SPIKES, KEEL) were virtually inserted into models of the distal tibias of 2 patients with end-stage ankle arthritis. Tibia models were generated from deidentified patient computed tomography scans, with material properties for modeling bone behavior and compaction during press-fit. Finite element analysis (FEA) was used to simulate 2 fixation configurations: (1) no sidewalls or interference fit, and (2) sidewalls with interference fit. Load profiles representing the stance phase of gait were applied to the models, and implant-bone micromotions were computed from FEA output. Results: Sidewalls and interference fit substantially influenced implant-bone micromotions across all designs studied. When sidewalls and interference fit were modeled, average micromotions were less than 11 µm, consistent across the stance phase of gait. Without sidewalls or interference fit, micromotions were largest near either heel strike or toe-off. In the absence of sidewalls and interference fit, the amount of micromotion generally aligned inversely with the size of implant fixation features; the ARC design had the largest micromotion (~540 µm average), whereas the KEEL design had the smallest micromotion (~15 µm). Conclusion: This study presents new insights into the effect of TAR fixation features on implant-bone micromotion. With sidewalls and interference fit, micromotion is predicted to be minimal for implants, whereas with no sidewalls and no interference fit, micromotion depended primarily on the implant design. Clinical Relevance: This study presents new insights into the effect of TAR primary fixation features on implant-bone micromotion. Although design features heavily influenced implant stability in the model, their influence was greatly diminished when interference fit was introduced. The results of this study show the relative importance of design features and interference fit in the predicted initial stability of uncemented TAR, potentially a key factor in implant survivorship.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
晚睡是小狗应助LX777采纳,获得10
1秒前
lcj1014完成签到,获得积分20
1秒前
1秒前
2秒前
科研通AI6.3应助福瑞灯采纳,获得10
4秒前
huangqian完成签到 ,获得积分10
4秒前
5秒前
猫绒球发布了新的文献求助10
5秒前
落晨发布了新的文献求助10
5秒前
6秒前
7秒前
JIA发布了新的文献求助10
7秒前
zulpikar发布了新的文献求助10
7秒前
panfengxing发布了新的文献求助10
7秒前
CipherSage应助明亮的夜梅采纳,获得10
7秒前
ethereal发布了新的文献求助10
7秒前
彭于晏应助冷酷保温杯采纳,获得10
8秒前
Lsy完成签到,获得积分10
8秒前
Ivonne发布了新的文献求助10
9秒前
9秒前
9秒前
淡定含烟完成签到,获得积分10
9秒前
10秒前
花花呀发布了新的文献求助20
10秒前
HHHHH发布了新的文献求助10
10秒前
10秒前
彭于晏应助snowdream采纳,获得10
10秒前
11秒前
NuyGinX完成签到 ,获得积分10
11秒前
11秒前
xiaohaitang发布了新的文献求助10
12秒前
12秒前
子文完成签到,获得积分10
13秒前
大气艳一完成签到,获得积分10
14秒前
14秒前
子非鱼发布了新的文献求助10
14秒前
14秒前
小沈发布了新的文献求助10
15秒前
15秒前
科研通AI6.2应助啊棕采纳,获得10
15秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Modern Epidemiology, Fourth Edition 5000
Digital Twins of Advanced Materials Processing 2000
Weaponeering, Fourth Edition – Two Volume SET 2000
Polymorphism and polytypism in crystals 1000
Signals, Systems, and Signal Processing 610
Discrete-Time Signals and Systems 610
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 纳米技术 有机化学 物理 生物化学 化学工程 计算机科学 复合材料 内科学 催化作用 光电子学 物理化学 电极 冶金 遗传学 细胞生物学
热门帖子
关注 科研通微信公众号,转发送积分 6023965
求助须知:如何正确求助?哪些是违规求助? 7653794
关于积分的说明 16174675
捐赠科研通 5172432
什么是DOI,文献DOI怎么找? 2767548
邀请新用户注册赠送积分活动 1750980
关于科研通互助平台的介绍 1637365