组内相关
威尔科克森符号秩检验
医学
核医学
图像质量
心室
置信区间
再现性
磁共振成像
心功能曲线
稳态自由进动成像
心脏病学
放射科
内科学
心力衰竭
人工智能
曼惠特尼U检验
数学
图像(数学)
计算机科学
统计
作者
Xianghu Yan,Yi Luo,Xiao Chen,Eric Z. Chen,Qi Liu,Lixian Zou,Yuwei Bao,Lu Huang,Liming Xia
摘要
Background Conventional segmented, retrospectively gated cine (Conv‐cine) is challenged in patients with breath‐hold difficulties. Compressed sensing (CS) has shown values in cine imaging but generally requires long reconstruction time. Recent artificial intelligence (AI) has demonstrated potential in fast cine imaging. Purpose To compare CS‐cine and AI‐cine with Conv‐cine in quantitative biventricular functions, image quality, and reconstruction time. Study Type Prospective human studies. Subjects 70 patients (age, 39 ± 15 years, 54.3% male). Field Strength/Sequence 3T; balanced steady state free precession gradient echo sequences. Assessment Biventricular functional parameters of CS‐, AI‐, and Conv‐cine were measured by two radiologists independently and compared. The scan and reconstruction time were recorded. Subjective scores of image quality were compared by three radiologists. Statistical Tests Paired t ‐test and two related‐samples Wilcoxon sign test were used to compare biventricular functional parameters between CS‐, AI‐, and Conv‐cine. Intraclass correlation coefficient (ICC), Bland–Altman analysis, and Kendall's W method were applied to evaluate agreement of biventricular functional parameters and image quality of these three sequences. A P ‐value <0.05 was considered statistically significant, and standardized mean difference (SMD) < 0. 100 was considered no significant difference. Results Compared to Conv‐cine, no statistically significant differences were identified in CS‐ and AI‐cine function results (all P > 0.05), except for very small differences in left ventricle end‐diastole volumes of 2.5 mL (SMD = 0.082) and 4.1 mL (SMD = 0.096), respectively. Bland–Altman scatter plots revealed that biventricular function results were mostly distributed within the 95% confidence interval. All parameters had acceptable to excellent interobserver agreements (ICC: 0.748–0.989). Compared with Conv‐cine (84 ± 13 sec), both CS (14 ± 2 sec) and AI (15 ± 2 sec) techniques reduced scan time. Compared with CS‐cine (304 ± 17 sec), AI‐cine (24 ± 4 sec) reduced reconstruction time. CS‐cine demonstrated significantly lower quality scores than Conv‐cine, while AI‐cine demonstrated similar scores ( P = 0.634). Conclusion CS‐ and AI‐cine can achieve whole‐heart cardiac cine imaging in a single breath‐hold. Both CS‐ and AI‐cine have the potential to supplement the gold standard Conv‐cine in studying biventricular functions and benefit patients having difficulties with breath‐holds. Level of Evidence 1 Technical Efficacy Stage 1
科研通智能强力驱动
Strongly Powered by AbleSci AI