放射性密度
医学
射线照相术
放射性武器
植入
髋臼
外科
牙科
作者
G. Macheras,Panayiotis J. Papagelopoulos,Konstantinos Kateros,A. Kostakos,Dimitrios Baltas,Theofilos Karachalios
出处
期刊:The journal of bone and joint surgery
[British Editorial Society of Bone and Joint Surgery]
日期:2006-02-23
卷期号:88-B (3): 304-309
被引量:107
标识
DOI:10.1302/0301-620x.88b3.16940
摘要
Between January 1998 and December 1998, 82 consecutive patients (86 hips) underwent total hip arthroplasty using a trabecular metal monoblock acetabular component. All patients had a clinical and radiological follow-up evaluation at six, 12 and 24 weeks, 12 months, and then annually thereafter. On the initial post-operative radiograph 25 hips had a gap between the outer surface of the component and the acetabular host bed which ranged from 1 to 5 mm. All patients were followed up clinically and radiologically for a mean of 7.3 years (7 to 7.5). The 25 hips with the 1 to 5 mm gaps were studied for component migration at two years using the Einzel-Bild-Roentgen-Analyse (EBRA) digital measurement method. At 24 weeks all the post-operative gaps were filled with bone and no acetabular component had migrated. The radiographic outcome of all 86 components showed no radiolucent lines and no evidence of lysis. No acetabular implant was revised. There were no dislocations or other complications. The bridging of the interface gaps (up to 5 mm) by the trabecular metal monoblock acetabular component indicates the strong osteoconductive, and possibly osteoinductive, properties of trabecular metal.
科研通智能强力驱动
Strongly Powered by AbleSci AI