溴酸盐
化学
溴化物
检出限
试剂
色谱法
相对标准差
臭氧
水消毒
无机化学
有机化学
废物管理
工程类
作者
Raquel B. R. Mesquita,Francisca T.S.M. Ferreira,Ana Teresa de Abreu Ramos-Cerqueira,António O. S. S. Rangel
出处
期刊:Analytical Sciences
[Japan Society for Analytical Chemistry]
日期:2022-01-01
卷期号:38 (1): 137-143
被引量:2
标识
DOI:10.2116/analsci.21p191
摘要
The aim of this work was the development of an automatic sequential injection analysis method to monitor the ozonation process for water disinfection. The determination was based on the reaction between bromate and o-dianisidine in the presence of bromide in acidic medium. The determination parameters were studied and adjusted to enable bromate quantification in the range 0.35–4.0 mg BrO3−/L with a limit of detection of 20 μg BrO3−/L. The choice of a sequential injection procedure enabled a minimal consumption of reagents and no need for sample pre-treatment. The developed sequential injection proved to be accurate with < 5% relative deviation when compared to ICP-MS and an average of 101% in recovery percentages studies. It was effectively applied to monitor an ozonation process enabling the follow-up of the process with real-time quantification of the bromate content.
科研通智能强力驱动
Strongly Powered by AbleSci AI