Sandrine Janine Lasance,Despina Koletsi,George Eliades,Theodore Eliades
摘要
Abstract The aim of this study was to assess the percentage degree of cure (DC%) of 2‐mm‐thick resin composite attachments used for aligner treatment. Three types of aligner – two thermoformed aligners (Clear Aligner [CLA], polyethylene terephthalate glycol modified; and Invisalign [INV], polyester urethane) and a three‐dimensional‐printed aligner (Graphy TC‐85DAC [GRP], an acrylate‐methacrylate copolymer) – were selected, along with two universal resin composites (3M Filtek Universal [FTU] and Charisma Topaz ONE [CTO]). Samples of each composite were placed under each aligner, and the degree of cure of each composite was evaluated on the top (facing the aligner) and the bottom (facing the substrate) attachment surfaces after curing. Five specimens were used per combination of aligner and composite, and an additional group of composites irradiated without aligners served as the control. The DC% measurements were performed using attenuated total reflection Fourier transform infrared (ATR‐FTIR) spectroscopy. The DC% across the aligners were (median values) 33.8%–44.8% for CLA, 33.6%–40.8% for INV, 32.8%–40.6% for GRP, and 40.0%–51.7% for the control group. The DC% values of the attachments cured under any aligner were significantly lower than that of the corresponding control, with the values recorded on the top surfaces being 6% higher than those on the bottom surfaces after adjusting for aligner group and composite type.