The cyclical variations in environmental temperature generated by natural rhythms constantly impact the wastewater treatment process through the aeration system. Engineering data show that fluctuations in environmental temperature cause the reactor temperature to drop at night, resulting in increased dissolved oxygen concentration and improved effluent wastewater quality. However, the impact of natural temperature variation on wastewater treatment systems and the energy-saving potential has yet to be fully recognized. Here, we conducted a comprehensive study, using a full-scale oxic-hydrolytic and denitrification-oxic (OHO) coking wastewater treatment process as a case and developed a dynamic aeration model integrating thermodynamics and kinetics to elucidate the energy-saving mechanisms of wastewater treatment systems in response to diurnal temperature variations. Our case study results indicate that natural diurnal temperature variations can cut the energy consumption of 660,980 kWh annually (up to 30%) for the aeration unit in the OHO system. Wastewater treatment facilities located in regions with significant environmental temperature variation stand to benefit more from this energy-saving mechanism. Methods such as flow dynamic control, load shifting, and process unit editing can be fitted into the new or retrofitted wastewater treatment engineering.