医学
肝细胞癌
冲刷
麦克内马尔试验
核医学
前瞻性队列研究
放射科
碘酰胺醇
胃肠病学
病理
内科学
造影剂
统计
数学
作者
Lingling Li,Xuebin Zou,Wei Zheng,Yu Hong Li,Xiaohong Xu,Kai Li,Zhongzhen Su,Jing Han,Qing Li,Yanling Zuo,Xie Shousong,Hong Wen,Jianwei Wang,Zhixing Guo,Ruhai Zou,Jianhua Zhou
出处
期刊:Radiology
[Radiological Society of North America]
日期:2023-08-01
卷期号:308 (2)
被引量:9
标识
DOI:10.1148/radiol.230150
摘要
Background Liver Imaging Reporting and Data System (LI-RADS) was designed for contrast-enhanced US (CEUS) with pure blood pool agents to diagnose hepatocellularfcarcinoma (HCC), such as sulfur hexafluoride (SHF), but Kupffer-cell agents, such as perfluorobutane (PFB), allow additional lesion characterization in the Kupffer phase yet remain unaddressed. Purpose To compare the diagnostic performance of three algorithms for HCC diagnosis: two algorithms based on CEUS LI-RADS version 2017 for both SHF and PFB and a modified algorithm incorporating Kupffer-phase findings for PFB. Materials and Methods This multicenter prospective study enrolled high-risk patients for HCC from June 2021 to December 2021. Each participant underwent same-day SHF-enhanced US followed by PFB-enhanced US. Each liver observation was assigned three LI-RADS categories according to each algorithm: LI-RADS SHF, LI-RADS PFB, and modified PFB. For modified PFB, observations at least 10 mm with nonrim arterial phase hyperenhancement were upgraded LR-4 to LR-5 if there was no washout with a Kupffer defect and were reassigned LR-M to LR-5 if there was early washout with mild Kupffer defect. The reference standard was pathologic confirmation or composite (typical CT or MRI features, or 1-year size stability and/or reduction). Diagnostic metrics of LR-5 for HCC using the three algorithms were calculated and compared using the McNemar test. Results Overall, 375 patients (mean age, 56 years ± 11 [SD]; 318 male patients, 57 female patients) with 424 observations (345 HCCs, 40 non-HCC malignancies, 39 benign lesions) were enrolled. PFB and SHF both using LI-RADS showed no significant difference in sensitivity (60% vs 58%; P = .41) and specificity (96% vs 95%; P > .99). The modified algorithm with PFB had increased sensitivity (80% vs 58%; P < .001) and a nonsignificant decrease in specificity (92% vs 95%; P = .73) compared with LI-RADS SHF. Conclusion Based on CEUS LI-RADS version 2017, both SHF and PFB achieved high specificity and relatively low sensitivity for HCC diagnosis. When incorporating Kupffer-phase findings, PFB had higher sensitivity without loss of specificity. Chinese Clinical Trial Registry no. ChiCTR2100047035 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Kim in this issue.
科研通智能强力驱动
Strongly Powered by AbleSci AI