作者
Frédéric Bouisset,Jussi Sia,Takuya Mizukami,Pasi P. Karjalainen,Pim A.L. Tonino,Nico H.J. Pijls,Jan Van der Heyden,Hannu Romppanen,Kari Kervinen,Juhani Airaksinen,Jacques Lalmand,Peter Frambach,Bruno R. da Costa,Carlos Collet,Bernard De Bruyne
摘要
Importance Titanium-nitride-oxide (TiNO)–coated stents show faster strut coverage compared with drug-eluting stents without excessive intimal-hyperplasia observed in bare metal stents. It is important to study long-term clinical outcomes after treatment of patients with an acute coronary syndrome (ACS) by TiNO-coated stents, which are neither drug-eluting stents nor bare metal stents. Objective To compare the rate of main composite outcome of cardiac death, myocardial infarction (MI), or ischemia-driven target lesion revascularization at 5 years in patients with ACS randomized to receive either a TiNO-coated stent or a third-generation everolimus-eluting stent (EES). Design, Setting, and Participants This multicenter, randomized, controlled, open-label trial was conducted in 12 clinical sites in 5 European countries and enrolled patients from January 2014 to August 2016. Patients presenting with ACS (ST-segment elevation MI, non–ST-segment elevation MI, and unstable angina) with at least 1 de novo lesion were randomized to receive either a TiNO-coated stent or an EES. The present report analyzes the long-term follow-up for the main composite outcome and its individual components. Analysis took place between November 2022 to March 2023. Main outcome The primary end point was a composite of cardiac death, MI, or target lesion revascularization at 12-month follow-up. Results A total of 1491 patients with ACS were randomly assigned to receive either TiNO-coated stents (989 [66.3%]) or EES (502 [33.7%]). The mean (SD) age was 62.7 (10.8) years, and 363 (24.3%) were female. At 5 years, the main composite outcome events occurred in 111 patients (11.2%) in the TiNO group vs 60 patients (12%) in the EES group (hazard ratio [HR], 0.94; 95% CI, 0.69-1.28; P = .69). The rate of cardiac death was 0.9% (9 of 989) vs 3.0% (15 of 502) (HR, 0.30; 95% CI, 0.13-0.69; P = .005), the rate of MI was 4.6% (45 of 989) vs 7.0% (35 of 502) (HR, 0.64; 95% CI, 0.41-0.99; P = .049), the rate of stent thrombosis was 1.2% (12 of 989) vs 2.8% (14 of 502) (HR, 0.43; 95% CI, 0.20-0.93; P = .034), and the rate of target lesion revascularization was 7.4% (73 of 989) vs 6.4% (32 of 502) (HR, 1.16; 95% CI, 0.77-1.76; P = .47) in the TiNO-coated stent arm and in the EES arm, respectively. Conclusion and relevance In this study, patients with ACS had a main composite outcome that was not different 5 years after TiNO-coated stent or EES. Trial Registration ClinicalTrials.gov Identifier: NCT02049229