环境科学
室内空气
室内空气质量
微粒
气象学
环境工程
地理
化学
有机化学
作者
Soo Bhin Park,Ju‐Hyeong Park,Young Min Jo,Doosam Song,Sujeong Heo,Tae Jeong Lee,Sowoo Park,Junemo Koo
标识
DOI:10.1016/j.buildenv.2021.108465
摘要
The Korean government recommends intermittent operation of air purifiers (APs) as a measure to maintain indoor particulate matter (PM) concentrations below the mandatory standards and reduce exposure to indr PM2.5 (PM with a diameter smaller than 2.5 μm). However, there is no guideline to inform occupants of when and how long APs should be operated to comply with the standards. In this study, we developed a dynamic mass-balance model to predict indoor PM concentrations in an office considering penetration of outdoor particles, change in number of occupants, and operational status of the AP. The model fit and prediction accuracies were verified using the American Society for Testing and Materials (ASTM) D 5157 criteria and the k-fold validation technique. We observed that indoor PM2.5 concentrations were determined by infiltration of outdoor PM2.5, and indoor generation/resuspension by occupants and removal. For PM2.5-10(2.5 μm
科研通智能强力驱动
Strongly Powered by AbleSci AI