医学
磁共振弥散成像
核医学
回波平面成像
膀胱癌
有效扩散系数
矢状面
磁共振成像
放射科
癌症
内科学
作者
Xiaoyan Meng,Henglong Hu,Yanchun Wang,Daoyu Hu,Zhen Li,Cui Feng
标识
DOI:10.1016/j.ejrad.2020.109486
摘要
Abstract
Objectives
To compare the image quality of the reduced field-of-view (rFOV) diffusion-weighted imaging (DWI) with the full field-of-view (fFOV) DWI in the assessment of bladder cancer (BC); and to explore the possible superiority of bi-planar (axial and sagittal) rFOV DWI over single planar fFOV DWI in predicting muscle-invasiveness of BC. Materials and methods
This retrospective study analyzed 61 patients with BC who underwent DWI sequences including axial fFOV DWI, axial rFOV DWI, and sagittal rFOV DWI. Qualitative and quantitative image quality assessment were compared between axial fFOV DWI and rFOV DWI sequences. The tumor with its base could be clearly displayed on DWI was defined as the evaluable lesion, and the number of evaluable lesions detected from single axial fFOV DWI, axial rFOV DWI, sagittal rFOV DWI, and bi-planar rFOV DWI sequences was recorded and compared. The apparent diffusion coefficient (ADC) was compared between non-muscular-invasive bladder cancer (NMIBC) and muscular-invasive bladder cancer (MIBC) based on the sequences of axial fFOV DWI and rFOV DWI, respectively. Vesical Imaging-Reporting and Data System (VI-RADS) was introduced to evaluate the overall risk of muscle-invasiveness of BC and receiver operating characteristic (ROC) curve analysis was applied to assess the diagnostic performance. Results
The contrast-to-noise ratio (CNR) of the rFOV DWI was significantly higher than that of fFOV DWI (p < 0.01), while the signal-to-noise ratio (SNR) was significantly lower than that of fFOV DWI (p < 0.01). The subjective score of rFOV DWI was significantly higher than that of fFOV DWI (p < 0.01). The ADC value of the MIBC group was significantly lower than that of the NMIBC in both rFOV DWI and fFOV DWI (all p < 0.01). The number of evaluable lesions detected from the bi-planar rFOV DWI was significantly higher than that detected from the single axial fFOV DWI, axial rFOV DWI, and sagittal rFOV DWI (all p < 0.01). VI-RADS based on the bi-planar rFOV DWI offered high predictive power (the area under the ROC curve, 0.946) for predicting the presence of muscle-invasiveness of BC. Conclusion
Bi-planar rFOV DWI may provide more diagnostic confidence than the single planar DWI for predicting the presence of muscle-invasiveness in BC, with improved image quality over the fFOV DWI.