Benchtop NIR data standardization on handheld spectrometers to identify paracetamol tablets

近红外光谱 分光计 移动设备 标准化 过程分析技术 化学计量学 可追溯性 校准 计算机科学 数学 光学 工程类 统计 化学工程 操作系统 软件工程 机器学习 物理 生物过程
作者
Corenthin Mees,Jean‐Michel Kauffmann,Juan Antonio Fernández Pierna,Kris De Braekeleer
出处
期刊:Journal of Chemometrics [Wiley]
卷期号:36 (3) 被引量:1
标识
DOI:10.1002/cem.3389
摘要

Abstract Near‐infrared spectroscopy (NIRS) allows innovative applications in terms of quality control, for example, in raw materials verification, in process analytical technology (PAT), and in discrimination between genuine and falsified medicines. The development of small and cheap handheld devices is expanding in the field, while trying to keep similar performances as benchtop instruments have. Considering traceability and quality control of drug compounds, this work is intended to identify 13 different paracetamol tablets on the Belgian market by using NIRS. The performances of a Fourier‐transform near‐infrared spectroscopy (FT‐NIR) benchtop and two handheld NIR spectrometers were investigated comparatively. All spectra were collected through the blister in the reflectance diffuse mode. NIR spectral fingerprints were pretreated and analyzed using principal component analysis (PCA) and classified with soft independent modeling of class analogy (SIMCA). The performances of the spectrometers were evaluated after standardization of the reference benchtop database to the handheld spectrometers. The instrumental response of the benchtop spectrometer was standardized towards the handheld device using the piecewise direct standardization (PDS) algorithm. These investigations permitted the advantages and limitations of NIR data standardization on predictive models to be pointed out. The SIMCA models based on the spectral data of the benchtop (B), handheld 1 (H1), and handheld 2 (H2) instruments had an accuracy of 99.2%, 97.7%, and 96.2%, respectively. The same accuracy was obtained with the models of the transferred benchtop spectra for the H1 and H2 devices. However, adding handheld spectra to the transferred benchtop spectra resulted in models with improved accuracy: from 97.7% to 98.5% for the H1 instrument and from 96.2% to 97.7% for the H2 instrument. The proposed strategy highlights the potential of using a reference database collected by NIRS for pharmaceutical analyses by handheld NIR spectrometers in terms of traceability.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
2秒前
3秒前
Venus发布了新的文献求助10
6秒前
Sally发布了新的文献求助10
7秒前
科研花完成签到 ,获得积分10
7秒前
吴妙竹hh完成签到 ,获得积分10
9秒前
Neon完成签到,获得积分10
9秒前
lesyeuxdexx完成签到 ,获得积分10
12秒前
范丞丞完成签到 ,获得积分10
13秒前
缓慢雅青完成签到,获得积分10
14秒前
15秒前
Sally完成签到,获得积分10
16秒前
16秒前
铅笔995发布了新的文献求助10
18秒前
殊途发布了新的文献求助10
19秒前
别找了睡觉吧完成签到 ,获得积分10
21秒前
21秒前
hhr驳回了HEIKU应助
22秒前
123完成签到 ,获得积分10
23秒前
CodeCraft应助殊途采纳,获得10
25秒前
咚咚完成签到 ,获得积分10
25秒前
26秒前
XU完成签到,获得积分10
26秒前
27秒前
ssl完成签到 ,获得积分10
29秒前
Keily发布了新的文献求助30
31秒前
32秒前
毛豆应助阿米尔盼盼采纳,获得10
32秒前
33秒前
34秒前
小刘哥儿完成签到,获得积分10
34秒前
ding应助科研通管家采纳,获得10
37秒前
FashionBoy应助科研通管家采纳,获得10
37秒前
37秒前
科研通AI2S应助科研通管家采纳,获得10
37秒前
冰生发布了新的文献求助10
38秒前
宁宁发布了新的文献求助10
40秒前
40秒前
122完成签到,获得积分20
40秒前
41秒前
高分求助中
Востребованный временем 2500
Hopemont Capacity Assessment Interview manual and scoring guide 1000
Injection and Compression Molding Fundamentals 1000
Classics in Total Synthesis IV: New Targets, Strategies, Methods 1000
Mantids of the euro-mediterranean area 600
The Oxford Handbook of Educational Psychology 600
Mantodea of the World: Species Catalog Andrew M 500
热门求助领域 (近24小时)
化学 医学 生物 材料科学 工程类 有机化学 生物化学 内科学 物理 纳米技术 计算机科学 基因 遗传学 化学工程 复合材料 免疫学 物理化学 细胞生物学 催化作用 病理
热门帖子
关注 科研通微信公众号,转发送积分 3422797
求助须知:如何正确求助?哪些是违规求助? 3023136
关于积分的说明 8903604
捐赠科研通 2710524
什么是DOI,文献DOI怎么找? 1486561
科研通“疑难数据库(出版商)”最低求助积分说明 687093
邀请新用户注册赠送积分活动 682326