Justine M. Ravaux,Michele Di Mauro,Kevin Vernooy,Arnoud W.J. van ’t Hof,Leo Veenstra,Suzanne Kats,Jos G. Maessen,Roberto Lorusso
出处
期刊:JTCVS open
[Elsevier]
日期:2021-02-16
卷期号:6: 41-55.e15
被引量:11
标识
DOI:10.1016/j.xjon.2021.02.002
摘要
Atrioventricular conductions disturbances, requiring permanent pacemaker implantation (PPI), represent a potential complication after transcatheter aortic valve implantation (TAVI), However, little is known about the pacemaker dependency after PPI in this patient setting. This systematic review analyses the incidence of PPI, the short-term (1-year) pacing dependency, and predictors for such a state after TAVI.We performed a systematic search in PUBMED, EMBASE, and MEDLINE to identify potentially relevant literature investigating PPI requirement and dependency after TAVI. Study data, patients, and procedural characteristics were extracted. Odds ratio (OR) with 95% confidence intervals were extracted.Data from 23 studies were obtained that included 18,610 patients. The crude incidence of PPI after TAVI was 17% (range, 8.8%-32%). PPI occurred at a median time of 3.2 days (range, 0-30 days). Pacing dependency at 1-year was 47.5% (range, 7%-89%). Self-expandable prosthesis (pooled OR was 2.14 [1.15-3.96]) and baseline right bundle branch block (pooled OR was 2.01 [1.06-3.83]) showed 2-fold greater risk to maintain PPI dependency at 1 year after TAVI.Although PPI represents a rather frequent event after TAVI, conduction disorders have a temporary nature in almost 50% of the cases with recovery and stabilization after discharge. Preoperative conduction abnormality and type of TAVI are associated with higher PPI dependency at short term.
科研通智能强力驱动
Strongly Powered by AbleSci AI