法布里-珀罗干涉仪
材料科学
磁场
光学
干涉测量
激光器
光纤
芯(光纤)
磁铁
灵敏度(控制系统)
联轴节(管道)
光电子学
复合材料
波长
物理
量子力学
电子工程
工程类
作者
Dengwei Zhang,Heming Wei,Huizhu Hu,Sridhar Krishnaswamy
出处
期刊:APL photonics
[AIP Publishing]
日期:2020-07-01
卷期号:5 (7): 076112-076112
被引量:56
摘要
In this paper, a polymer micro-Fabry–Pérot interferometer (FPI) fabricated via direct laser writing using two-photon polymerization techniques on a single mode fiber tip is proposed, designed, simulated, and experimentally demonstrated as a magnetic field probe. The sensor comprises a tapered waveguide with a length of 100 µm and a diameter of 1 µm along the axis connecting the two reflecting surfaces of the micro-FPI open cavity. The cavity is filled with a magnetic fluid (MF) changing the evanescent coupling and consequently leading to a change in the phase of the FPI. To improve the signal reflection, a thin layer of Au is coated on the device before fabricating the probe sensor, which is then sealed in a MF-filled glass tube. The experimental results show that the proposed probe sensor has a low temperature sensitivity and a sensitivity to magnetic field as high as 1.54 nm/mT, and the magnetic field measurement accuracy is ∼649.4 μT within a range from 1 mT to 8 mT. The microsensor, which is very stable and easy to fabricate, can be used as a probe to detect weak magnetic fields.
科研通智能强力驱动
Strongly Powered by AbleSci AI