脂质体
体积流量
工艺工程
分散性
水溶液
混合(物理)
计算机科学
材料科学
色谱法
化学
纳米技术
工程类
热力学
有机化学
物理
量子力学
作者
Sarah Lindsay,Olympia Tumolva,Tatsiana Khamiakova,Hans Coppenolle,Martin Kovářík,Sanket Shah,René Holm,Yvonne Perrie
出处
期刊:Pharmaceutics
[MDPI AG]
日期:2024-09-01
卷期号:16 (9): 1159-1159
标识
DOI:10.3390/pharmaceutics16091159
摘要
Microfluidic liposome production presents a streamlined pathway for expediting the translation of liposomal formulations from the laboratory setting to clinical applications. Using this production method, resultant liposome characteristics can be tuned through the control of both the formulation parameters (including the lipids and solvents used) and production parameters (including the production speed and mixing ratio). Therefore, the aim of this study was to investigate the relationship between not only total flow rate (TFR), the fraction of the aqueous flow rate over the organic flow rate (flow rate ratio (FRR)), and the lipid concentration, but also the solvent selection, aqueous buffer, and production temperature. To achieve this, we used temperature, applying a design of experiment (DoE) combined with machine learning. This study demonstrated that liposome size and polydispersity were influenced by manipulation of not only the total flow rate and flow rate ratio but also through the lipids, lipid concentration, and solvent selection, such that liposome attributes can be in-process controlled, and all factors should be considered within a manufacturing process as impacting on liposome critical quality attributes.
科研通智能强力驱动
Strongly Powered by AbleSci AI