组内相关
核医学
医学
磁共振成像
灌注
头颈部鳞状细胞癌
动脉自旋标记
感兴趣区域
动态增强MRI
血流
放射科
头颈部癌
放射治疗
临床心理学
心理测量学
作者
Noriyuki Fujima,Kohsuke Kudo,Akiko Tsukahara,Daisuke Yoshida,Tomohiro Sakashita,Akihiro Homma,Khin Khin Tha,Hiroki Shirato
摘要
To investigate the feasibility of tumor blood flow (TBF) measurement in head and neck squamous cell carcinoma (HNSCC) using pseudo-continuous arterial spin labeling (pCASL) in a comparison with dynamic contrast-enhanced (DCE) perfusion.We prospectively scanned 18 patients with HNSCC using 3T magnetic resonance imaging (MRI) with both pCASL and DCE perfusion. Quantitative TBF value in the whole-tumor region of interest (ROI), and regional TBF in the ROIs of the central and peripheral areas in the tumor were respectively measured. Relative TBF value in the whole-tumor ROI was also calculated. We determined the correlation and agreement between each measured TBF by pCASL and DCE perfusion using Pearson's correlation coefficients, intraclass correlation coefficients (ICC), and Bland-Altman analysis.In the whole-tumor ROIs, significant correlation was observed between the absolute TBF values (r = 0.72, P < 0.01), with an ICC of 0.72; moreover, higher correlation was observed in the relative TBF (r = 0.79). The correlation was higher in the peripheral ROI (r = 0.70) than the central ROI (r = 0.65), with an ICC of 0.62 and 0.54, respectively. Bland-Altman plots revealed the underestimation of TBF by pCASL in central ROIs.TBF measurement by pCASL was feasible in patients with HNSCC. J. Magn. Reson. Imaging 2015;41:1-1. © 2014 Wiley Periodicals, Inc.
科研通智能强力驱动
Strongly Powered by AbleSci AI