医学
牵张成骨
分散注意力
外固定器
口腔正畸科
胫骨
生物力学
骨科手术
外科
解剖
神经科学
生物
作者
James Aronson,J H Harp
出处
期刊:PubMed
日期:1994-04-01
卷期号: (301): 73-9
被引量:44
标识
DOI:10.1097/00003086-199404000-00013
摘要
Direct axial loads were measured weekly during a 15% left tibial lengthening in 21 skeletally mature dogs using three in-line load cells mounted between the rings of an Ilizarov external fixator. The loads increased linearly over time to a maximum at the end of distraction (Week 4). The metaphyseal lengthening sites (mean, 155 N) generated significantly higher loads than diaphyseal sites (mean, 111 N). Stress was calculated by dividing measured load by the computed tomographic-measured cross-sectional area of each distraction osteogenesis site; the metaphyseal and diaphyseal groups demonstrated equal stress at each time point with a maximum of 47 N/cm2 at the end of distraction. Six premature consolidations occurred that demonstrated loads significantly greater than 200 N by Week 2 of distraction. Three nonunions occurred that had significantly lower loads measured by Week 3 of distraction (mean, 60 N or 26 N/cm2).
科研通智能强力驱动
Strongly Powered by AbleSci AI