作者
Wesley L. Anderson,Pantila Bateman,Susan Ofner,Xiaochun Li,Benjamin Maatman,Deborah Green‐Hess,Stephen G. Sawada,Harvey Feigenbaum
摘要
•Sensitivity of strain parameters exceeds that of WMA. •PSSi has the best balance of sensitivity and specificity. •Adding strain parameters to DSE in ESLD increases sensitivity. Background Dobutamine stress echocardiography (DSE) remains a widely used method for detection of coronary artery disease (CAD) in patients with end-stage liver disease (ESLD) despite low sensitivity. Speckle-tracking assessment of strain may enhance the sensitivity of DSE in the general population, but the value of strain analysis in ESLD is unknown. Methods Dobutamine stress echocardiography with two-dimensional speckle-tracking and quantitative coronary angiography were performed in 146 patients with ESLD. Thirty-six patients (25%) had CAD (≥50% diameter stenosis of a major vessel). Global longitudinal strain at rest (GLSr) and at peak stress (GLSp) and an index of postsystolic (PSSi) shortening ([maximal extent of shortening – extent of shortening in systole]/[extent of shortening in systole]) were determined. A PSSi of ≥ 0.25 was considered evidence for CAD. Receiver operating characteristic analysis was used to determine the optimal thresholds of GLSr and GLSp for CAD and to assess the diagnostic performance of visual assessment of wall motion (WMA) and strain parameters. The sensitivity and specificity of WMA, GLSr, GLSp, and PSSi were compared. Results Thirty-six patients (25%) had significant CAD. The areas under the curve for WMA, GLSr, GLSp, and PSSi were 0.60, 0.72, 0.68, and 0.78, respectively. Visual assessment of wall motion had a sensitivity of 28%. The sensitivity of each of the strain parameters, GLSr (53%, P = .016), GLSp (69%, P = .004), and PSSi (78%, P < .001), exceeded the sensitivity for WMA. Visual assessment of wall motion specificity was 92%, which exceeded the specificity for each of the strain parameters (GLSr = 82%, P = .037; GLSp = 63%, P < .001; and PSSi =78%, P = .009). Of the strain parameters, PSSi had the best balance between sensitivity and specificity (both 78%). Conclusion Assessment of GLS and PSSi with DSE yields better sensitivity than WMA in ELSD patients. Index of postsystolic shortening had the best diagnostic performance of all parameters in this population with a low prevalence of CAD. Dobutamine stress echocardiography (DSE) remains a widely used method for detection of coronary artery disease (CAD) in patients with end-stage liver disease (ESLD) despite low sensitivity. Speckle-tracking assessment of strain may enhance the sensitivity of DSE in the general population, but the value of strain analysis in ESLD is unknown. Dobutamine stress echocardiography with two-dimensional speckle-tracking and quantitative coronary angiography were performed in 146 patients with ESLD. Thirty-six patients (25%) had CAD (≥50% diameter stenosis of a major vessel). Global longitudinal strain at rest (GLSr) and at peak stress (GLSp) and an index of postsystolic (PSSi) shortening ([maximal extent of shortening – extent of shortening in systole]/[extent of shortening in systole]) were determined. A PSSi of ≥ 0.25 was considered evidence for CAD. Receiver operating characteristic analysis was used to determine the optimal thresholds of GLSr and GLSp for CAD and to assess the diagnostic performance of visual assessment of wall motion (WMA) and strain parameters. The sensitivity and specificity of WMA, GLSr, GLSp, and PSSi were compared. Thirty-six patients (25%) had significant CAD. The areas under the curve for WMA, GLSr, GLSp, and PSSi were 0.60, 0.72, 0.68, and 0.78, respectively. Visual assessment of wall motion had a sensitivity of 28%. The sensitivity of each of the strain parameters, GLSr (53%, P = .016), GLSp (69%, P = .004), and PSSi (78%, P < .001), exceeded the sensitivity for WMA. Visual assessment of wall motion specificity was 92%, which exceeded the specificity for each of the strain parameters (GLSr = 82%, P = .037; GLSp = 63%, P < .001; and PSSi =78%, P = .009). Of the strain parameters, PSSi had the best balance between sensitivity and specificity (both 78%). Assessment of GLS and PSSi with DSE yields better sensitivity than WMA in ELSD patients. Index of postsystolic shortening had the best diagnostic performance of all parameters in this population with a low prevalence of CAD.