Sheren M. Diab,Heba A. Al-Metyazidy,Soheir Mohamed Weheida,Sabry Mohamed Amin,Zainab Allam
出处
期刊:Egyptian Journal of Health Care
[Egypts Presidential Specialized Council for Education and Scientific Research]
日期:2021-09-01
卷期号:12 (3): 323-340
标识
DOI:10.21608/ejhc.2021.190401
摘要
Background: Continuous changes in central venous pressure monitoring among critically ill
patients was allied to fluid response. External jugular venous pressure may be a reliable
estimation method to central venous pressure and have the advantages of being less invasive.
Setting: This study was conducted at the anesthesia Intensive Care Unit at Emergency Hospital
affiliated to Tanta University Hospitals, Egypt. The aim of the study was to estimate external
jugular venous pressure versus central venous pressure measurement as a clinical predictor
among critically ill mechanically ventilated patients Method: A prospective comparative study
design was utilized in the current study. A purposive sample of 30 adults mechanically
ventilated patients was included in this study. Two tools were utilized to collect data: Tool (I):
Mechanically ventilated patient assessment and Tool II: Central venous pressure and External
jugular venous pressure assessment. Results: It was observed that there was a highly positive
and significant correlation between central venous pressure and external jugular venous
pressure reading r= 0.813 and p=0,000. Conclusions: External jugular venous pressure
measurement represented a real value of central venous pressure. A positive statistical
correlation between central venous pressure and external jugular venous pressure
measurements seems to be a reliable method to differentiate mechanically ventilated patients
with high or low central venous pressure monitoring. Recommendations: Measurement of
external jugular venous pressure should be integrated within the critically ill patient's routine
care Measurement. Also Measuring central venous pressure may be replaced with external
jugularvenous pressure (EJVP) when indicated. Further studies will be needed to confirm
reliability of the EJVP on a larger probability sample.