色谱法
化学
分析物
对映体
质谱法
电喷雾电离
串联质谱法
选择性反应监测
检出限
液相色谱-质谱法
电喷雾
分析化学(期刊)
立体化学
作者
Jilei Zhang,Rong Wang,Hua Xie,Xiandong Meng,Zhengping Jia,Jun Ma,Junli Zhang,Juan Wang
出处
期刊:Sepu
[Science Press]
日期:2011-03-02
卷期号:29 (1): 26-30
被引量:3
标识
DOI:10.3724/sp.j.1123.2011.00026
摘要
A rapid and sensitive method was developed and validated using a normal phase liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) for determination of propranolol enantiomers in pharmaceuticals. Sample preparation involved a single extraction step by the addition of methanol. Separation of propranolol enantiomers was achieved on a Chiralcel OD-H chiral column using a mobile phase consisting of n-hexane-ethanol-ammonia (70:30:0.4, v/v/v), and the flow rate was 0.40 mL/min for 20 min. The analyte was monitored by tandem mass spectrometry with electrospray positive ionization in multiple reaction monitoring (MRM) mode, using the transitions of m/z 260.2 --> 116.0. Propranolol enantiomers can be completely separated. The linear range was 2.5-1000 microg/L, and the limit of quantification (LOQ) was 2.5 microg/L. The values for within day and between day precisions and accuracies were well within the generally accepted criteria for analytical methods. The relative standard deviations (RSDs) were less than 2.64%, and the recoveries of the two enantiomers were 99.08%-102.58% and 100.21%-103.16%, respectively. The separation method is accurate, convenient, reliable, efficient, and can be subsequently used for quality control of propranolol enantiomers in pharmaceuticals.