The hepatic venous pressure gradient: Anything worth doing should be done right

门静脉压 医学 心脏病学 内科学 门脉高压 肝硬化
作者
Roberto J. Groszmann,Suchat Wongcharatrawee
出处
期刊:Hepatology [Wiley]
卷期号:39 (2): 280-283 被引量:462
标识
DOI:10.1002/hep.20062
摘要

WHVP, wedged hepatic venous pressure; FHVP, free hepatic venous pressure; HVPG, hepatic venous pressure gradient; PVP, portal venous pressure. Over the last two decades, our understanding of the treatment and prognosis of portal hypertension has continued to improve.1, 2 The use of techniques to measure the wedged hepatic venous pressure (WHVP), developed more than 50 years ago, has played a major role in elucidating the pathophysiology of the syndrome3 and, consequently, in developing currently available pharmacologic therapy. Recently, a role for measurements of WHVP has also been proposed in evaluating the progression of chronic liver diseases.4 This measurement has been shown to be the best predictor of the development of complications of portal hypertension in patients with early cirrhosis.5 Investigators in this area of research need not be convinced about the importance of the WHVP technique in advancing our knowledge of portal hypertension from the experimental arena3 to current clinical applications.6-8 However, there is an unanswered question that has lingered with us for more than 20 years: Should measurement of WHVP be incorporated into clinical practice? To begin to answer this question, we must assure ourselves that the technique is executed properly. In a recent study performed to evaluate a new pharmaceutical agent, one of us (R.J.G.) was asked to be a blind reviewer of WHVP tracings performed by centers experienced in the measurement of WHVP. Even though minimal criteria for acceptable measurements have been established (Table 1), approximately 30% of studies% had to be rejected as the tracings obtained were uninterpretable. Our experience is not unique (Jaime Bosch, personal communication). We cannot draw conclusions about the usefulness of this technique in a clinical setting if investigational studies designed to answer the question do not themselves comply with minimal criteria for technical adequacy. To achieve results that are consistent and comparable from center to center, meticulous attention to detail is required (Table 1). 1. Use an appropriate scale. Venous pressures have an upper range of approximately 30–40 mm Hg. Therefore, scales used for arterial pressure measurements are not adequate. To be able to detect small changes, the scale should be set at 1 mm Hg = 1 mm on the scale (or more, e.g., 1 mm Hg = 2.5 mm on the scale; Fig. 2). 5. Check the inflated balloon for total occlusion of the hepatic vein (Fig. 1). If it is not (e.g., venous-to-venous shunts, insufficient inflation of the balloon), the measurements should be repeated either by moving the balloon catheter distal to the venous-to-venous shunts, or, when the drainage is to another hepatic vein, by changing the position of the catheter to another hepatic vein without venous-to-venous shunts. A hepatic vein that drains into another hepatic vein or distal to the balloon occlusion will underestimate the WHVP. In rare cases, the measurement cannot be accomplished. Checking for total occlusion of the balloon (wedged position) should be performed at the end of the measurement by slowly injecting 5 mL of contrast into the hepatic vein while the balloon is inflated. This should show the typical wedged (sinusoidal) pattern and no communication with other hepatic veins. After deflating the balloon the dye should wash out quickly. Do this consistently (i.e., do not check for balloon occlusion before measurements on one procedure and after the measurements in another). Direct measurement of portal venous pressure (PVP) is invasive and inconvenient. In 1951, Myers and Taylor9 first described WHVP, which is the measurement of the sinusoidal pressure, an indirect measurement of PVP. Since then, WHVP has been shown to be very safe and the rate of successful hepatic vein catheterization is greater than 95%. By threading a small catheter into a hepatic vein until it cannot be advanced further, a “wedged” hepatic venous pressure is obtained. As the hepatic vein is occluded, a continuous column of fluid between the catheter and the sinusoid is formed, resulting in a pressure reading that is equal to the sinusoidal pressure (Fig. 1). In normal livers, the low-resistant sinusoidal network dissipates most of the pressure back up from the wedged catheter. As there is no direct connection, via a static column of fluid, between the catheter and the portal tributaries, the pressure reading of the transducer reflects sinusoidal pressure (in normal livers is slightly lower than portal pressure). This is also observed in presinusoidal causes of portal hypertension such as schistosomiasis or early primary biliary cirrhosis. Because the catheter in these cases is not in continuity with the area of increased resistance, the recorded pressure will be that of the normal sinusoids and not of the increased pressure in the portal vein. In these cases, WHVP will be an underestimation of the PVP.11, 12 Conversely, in alcoholic cirrhosis and in most cases of hepatitis C and B virus-induced cirrhosis, connections between sinusoids are decreased because of narrowing of the sinusoidal vascular bed (caused by collagen deposition in the space of Disse, compression by regenerative nodules, and microthrombosis). As there is little dissipation of pressure in the narrowed sinusoids, the static column of blood extends from the catheter to the portal vein and the WHVP is virtually equal to the PVP (Fig. 1).3, 11-14 (A) The pressure transducer on the straight catheter is wedged into a small hepatic vein. Because there is a regional variability of fibrosis, the WHVP of the more fibrotic area (inset 1) is higher than that of the relatively normal parenchyma (inset 2). (B) The balloon catheter eliminates this inconsistency by averaging WHVP over a wider segment of the liver. Currently, the most commonly utilized parameter is not the WHVP, but hepatic venous pressure gradient (HVPG), the difference between WHVP and free hepatic venous pressure (FHVP). HVPG represents the gradient between the portal vein and the intraabdominal vena caval pressure. Whereas both the WHVP and FHVP are affected equally by intraabdominal pressure, their gradient, HVPG, is not. Unlike PVP or WHVP, which can be elevated falsely in the presence of ascites and elevated intraabdominal pressure, the measurement of HVPG incorporates its own zero reference point and is not affected by increases in intraabdominal pressure. Furthermore, the use of the HVPG eliminates another very important source of error, the external zero reference point, which may vary from center to center. A recent study indicates differences in the values obtained when the catheter is wedged in different hepatic veins, which is a cause of concern.15 These differences probably may be due to the heterogeneity of sinusoidal involvement by the disease process affecting the liver. The smaller the vein where the catheter is wedged, the greater the potential discrepancy with a subsequent measurement in a different hepatic vein. This observation reflects the finding that cirrhosis is not a homogeneous disease.16, 17 The use of a balloon-tipped catheter18 (Fig. 1) versus a straight catheter provides both theoretical and practical advantages. The balloon catheter occludes a larger hepatic venous branch and can, theoretically, measure WHVP over a wider vascular territory of the liver compared with the straight catheter. The use of balloon catheter also provides a practical advantage as it allows repeated measurements from the same hepatic vein and avoids the decompressive effect of venous-to-venous shunts that are proximal to the balloon. Conversely, a straight catheter has to be advanced and withdrawn for each WHVP and FHVP measurement, making it difficult to wedge the same venule with each successive pressure determination. Having experience with this procedure for more than 25 years, we are confident that properly executed, the balloon catheter technique produces HVPG values that are accurate and reproducible. Adherence to guidelines suggested in Table 1 is extremely important. Furthermore, pressure tracings should be annotated and recorded so that they can be reviewed subsequently by an independent observer (Fig. 2). The pressure transducer needs to be calibrated carefully against known external pressure. (Top), a 13.6-cm and a 27.2-cm column of water are used to calibrate the transducer to 10 and 20 mm Hg, respectively. Pressure readings are obtained by averaging values of stable tracings as shown in the highlighted area. We use the arithmetic function built into the tracing recorder to calculate the mean pressures for the inferior vena cava (IVC), FHVP, and WHVP. A stable tracing of 45 to 60 seconds is necessary for WHVP measurement whereas a tracing of 15 to 20 seconds is adequate for IVC and FHVP measurement. In summary, we do not believe that proponents of HVPG measurement have overemphasized its importance. Even if this method does not achieve the clinical utility that many of us believe it should, we have no doubt of the importance that it played and is still playing in advancing our knowledge of the portal hypertensive syndrome. What is also clear to us is that to reach any conclusion about this technique, one must first ensure that the technique is performed properly.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
大幅提高文件上传限制,最高150M (2024-4-1)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
1秒前
Liu完成签到 ,获得积分10
1秒前
ChouNic完成签到 ,获得积分10
2秒前
shuhaha完成签到,获得积分10
2秒前
糖伯虎完成签到 ,获得积分10
2秒前
木子完成签到,获得积分20
2秒前
czb666发布了新的文献求助10
4秒前
5秒前
木子发布了新的文献求助10
6秒前
一小部分我完成签到 ,获得积分10
7秒前
喜宝完成签到 ,获得积分10
8秒前
飘逸问薇完成签到 ,获得积分10
23秒前
峰feng完成签到 ,获得积分10
27秒前
32秒前
清爽老九应助zxdawn采纳,获得10
33秒前
DD完成签到,获得积分20
34秒前
yang完成签到 ,获得积分10
35秒前
顽固分子完成签到 ,获得积分10
36秒前
DD发布了新的文献求助10
36秒前
wykion完成签到,获得积分10
36秒前
NexusExplorer应助缥缈不惜采纳,获得10
36秒前
吾日三省吾身完成签到 ,获得积分10
41秒前
赘婿应助态度采纳,获得10
42秒前
42秒前
RTP完成签到 ,获得积分10
44秒前
45秒前
斯文的苡完成签到,获得积分10
46秒前
脑洞疼应助加油采纳,获得10
46秒前
52秒前
future完成签到 ,获得积分10
55秒前
amengptsd完成签到,获得积分10
55秒前
加油完成签到,获得积分20
55秒前
yoyo完成签到,获得积分10
57秒前
加油发布了新的文献求助10
58秒前
哆啦A梦完成签到 ,获得积分10
59秒前
快乐迎心完成签到,获得积分20
1分钟前
1分钟前
1分钟前
科研通AI2S应助科研通管家采纳,获得10
1分钟前
Eternal完成签到 ,获得积分10
1分钟前
高分求助中
Licensing Deals in Pharmaceuticals 2019-2024 3000
Cognitive Paradigms in Knowledge Organisation 2000
Introduction to Spectroscopic Ellipsometry of Thin Film Materials Instrumentation, Data Analysis, and Applications 1800
Natural History of Mantodea 螳螂的自然史 1000
A Photographic Guide to Mantis of China 常见螳螂野外识别手册 800
How Maoism Was Made: Reconstructing China, 1949-1965 800
Barge Mooring (Oilfield Seamanship Series Volume 6) 600
热门求助领域 (近24小时)
化学 医学 生物 材料科学 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 基因 遗传学 催化作用 物理化学 免疫学 量子力学 细胞生物学
热门帖子
关注 科研通微信公众号,转发送积分 3314323
求助须知:如何正确求助?哪些是违规求助? 2946587
关于积分的说明 8530889
捐赠科研通 2622334
什么是DOI,文献DOI怎么找? 1434442
科研通“疑难数据库(出版商)”最低求助积分说明 665312
邀请新用户注册赠送积分活动 650855