医学
颈部疼痛
外科
假肢
脊髓病
运动范围
颈椎病
颈椎
射线照相术
脊髓
替代医学
病理
精神科
作者
Jan Goffin,Johan van Loon,Frank Van Calenbergh,Bailey Lipscomb
出处
期刊:Journal of neurosurgery
[Journal of Neurosurgery Publishing Group]
日期:2010-03-01
卷期号:12 (3): 261-269
被引量:91
标识
DOI:10.3171/2009.9.spine09129
摘要
Object In this study, long-term results are presented from clinical studies of the Bryan Cervical Disc Prosthesis at University Hospital Gasthuisberg in Leuven, Belgium. A total of 98 patients (89 with 1-level and 9 with 2-level implantations) agreed to participate in follow-up studies for up to 10 years postoperatively. This article focuses on the 4- and 6-year results. Patients in one of the clinical studies had either radiculopathy or myelopathy associated with spondylosis and/or disc herniations that did not respond to conservative treatment. Patients from the other clinical study received commercially available Bryan devices and the study protocol did not have specific inclusion/exclusion criteria. More than 90% of the patients were considered to have radiculopathy. Methods Clinical measurements discussed in the article include the 36-Item Short Form Health Survey, Neck Disability Index, numerical ratings of neck and arm pain, neurological outcomes, and Odom classification. Angular motion findings from lateral flexion-extension radiographs are also presented. The occurrence of adverse events and second surgeries are examined as an indicator of device safety. Results The clinical outcomes at 4 and 6 years postoperatively appear consistent with the previously reported results at 1 and 2 years postoperatively. The mean angular motion results at 4 and 6 years postoperatively for 1-level patients were 7.3 and 7.7°, respectively. Two-level patients had slightly less motion at 4 and 6 years postoperatively with mean caudad values of 5.7 and 6.0°, respectively, and cephalad values of 4.2 and 6.2°, respectively. Efforts were made to capture adverse events, regardless of their nature and relatedness to the study surgery. This effort resulted in a relatively high number of recorded events. However, only 6 patients experienced events that were judged by the investigator to be related, either possibly or definitely, to the Bryan device. These events included device migration, device removal, and hoarseness and vocal cord paralysis, as well as 3 cases involving pain and neurological symptoms. Eight patients underwent further neck surgery to treat symptoms. Conclusions The favorable clinical and angular motion outcomes that were previously noted at 1- and 2-years' follow-up after cervical disc replacement with the Bryan Cervical Disc Prosthesis appear to persist after 4 and 6 years of follow-up.
科研通智能强力驱动
Strongly Powered by AbleSci AI