Towards subpercentage uncertainty proton stopping‐power mapping via dual‐energy CT: Direct experimental validation and uncertainty analysis of a statistical iterative image reconstruction method

扫描仪 迭代重建 数字增强无线通信 物理 核医学 光学 计算机科学 人工智能 医学 电信 无线
作者
María Medrano,Ruirui Liu,Tianyu Zhao,T. B. Webb,David G. Politte,Bruce R. Whiting,Rui Liao,Tao Ge,Mariela A. Porras‐Chaverri,Joseph A. O’Sullivan,Jeffrey F. Williamson
出处
期刊:Medical Physics [Wiley]
卷期号:49 (3): 1599-1618 被引量:7
标识
DOI:10.1002/mp.15457
摘要

To assess the potential of a joint dual-energy computerized tomography (CT) reconstruction process (statistical image reconstruction method built on a basis vector model (JSIR-BVM)) implemented on a 16-slice commercial CT scanner to measure high spatial resolution stopping-power ratio (SPR) maps with uncertainties of less than 1%.JSIR-BVM was used to reconstruct images of effective electron density and mean excitation energy from dual-energy CT (DECT) sinograms for 10 high-purity samples of known density and atomic composition inserted into head and body phantoms. The measured DECT data consisted of 90 and 140 kVp axial sinograms serially acquired on a Philips Brilliance Big Bore CT scanner without beam-hardening corrections. The corresponding SPRs were subsequently measured directly via ion chamber measurements on a MEVION S250 superconducting synchrocyclotron and evaluated theoretically from the known sample compositions and densities. Deviations of JSIR-BVM SPR values from their theoretically calculated and directly measured ground-truth values were evaluated for our JSIR-BVM method and our implementation of the Hünemohr-Saito (H-S) DECT image-domain decomposition technique for SPR imaging. A thorough uncertainty analysis was then performed for five different scenarios (comparison of JSIR-BVM stopping-power ratio/stopping power (SPR/SP) to International Commission on Radiation Measurements and Units benchmarks; comparison of JSIR-BVM SPR to measured benchmarks; and uncertainties in JSIR-BVM SPR/SP maps for patients of unknown composition) per the Joint Committee for Guides in Metrology and the Guide to Expression of Uncertainty in Measurement, including the impact of uncertainties in measured photon spectra, sample composition and density, photon cross section and I-value models, and random measurement uncertainty. Estimated SPR uncertainty for three main tissue groups in patients of unknown composition and the weighted proportion of each tissue type for three proton treatment sites were then used to derive a composite range uncertainty for our method.Mean JSIR-BVM SPR estimates deviated by less than 1% from their theoretical and directly measured ground-truth values for most inserts and phantom geometries except for high-density Delrin and Teflon samples with SPR error relative to proton measurements of 1.1% and -1.0% (head phantom) and 1.1% and -1.1% (body phantom). The overall root-mean-square (RMS) deviations over all samples were 0.39% and 0.52% (head phantom) and 0.43% and 0.57% (body phantom) relative to theoretical and directly measured ground-truth SPRs, respectively. The corresponding RMS (maximum) errors for the image-domain decomposition method were 2.68% and 2.73% (4.68% and 4.99%) for the head phantom and 0.71% and 0.87% (1.37% and 1.66%) for the body phantom. Compared to H-S SPR maps, JSIR-BVM yielded 30% sharper and twofold sharper images for soft tissues and bone-like surrogates, respectively, while reducing noise by factors of 6 and 3, respectively. The uncertainty (coverage factor k = 1) of the DECT-to-benchmark values comparison ranged from 0.5% to 1.5% and is dominated by scanning-beam photon-spectra uncertainties. An analysis of the SPR uncertainty for patients of unknown composition showed a JSIR-BVM uncertainty of 0.65%, 1.21%, and 0.77% for soft-, lung-, and bony-tissue groups which led to a composite range uncertainty of 0.6-0.9%.Observed JSIR-BVM SPR estimation errors were all less than 50% of the estimated k = 1 total uncertainty of our benchmarking experiment, demonstrating that JSIR-BVM high spatial resolution, low-noise SPR mapping is feasible and is robust to variations in the geometry of the scanned object. In contrast, the much larger H-S SPR estimation errors are dominated by imaging noise and residual beam-hardening artifacts. While the uncertainties characteristic of our current JSIR-BVM implementation can be as large as 1.5%, achieving < 1% total uncertainty is feasible by improving the accuracy of scanner-specific scatter-profile and photon-spectrum estimates. With its robustness to beam-hardening artifact, image noise, and variations in phantom size and geometry, JSIR-BVM has the potential to achieve high spatial-resolution SPR mapping with subpercentage accuracy and estimated uncertainty in the clinical setting.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
潘潘发布了新的文献求助10
3秒前
3秒前
nianbing发布了新的文献求助10
4秒前
呃呃呃c发布了新的文献求助30
6秒前
鸣笛应助和谐的阁采纳,获得50
7秒前
7秒前
直觉应助obsidian采纳,获得10
9秒前
112345发布了新的文献求助10
10秒前
LL发布了新的文献求助10
12秒前
13秒前
Akim应助优美的世开采纳,获得10
13秒前
醉熏的沛容完成签到,获得积分10
13秒前
13秒前
14秒前
zhangyu应助Tsui采纳,获得40
14秒前
丘比特应助林海国采纳,获得20
15秒前
Jasper应助科研达人采纳,获得10
16秒前
忘尘完成签到 ,获得积分20
18秒前
20秒前
20秒前
甜甜玫瑰应助一叶知秋采纳,获得10
21秒前
wanxing发布了新的文献求助10
22秒前
25秒前
NexusExplorer应助domingo采纳,获得10
25秒前
科研通AI5应助Flames采纳,获得10
25秒前
25秒前
缥缈书本完成签到 ,获得积分10
26秒前
害羞的凝竹完成签到 ,获得积分10
26秒前
27秒前
LL完成签到,获得积分10
28秒前
Csg完成签到,获得积分10
30秒前
haochi发布了新的文献求助10
31秒前
楠木完成签到,获得积分10
31秒前
help完成签到 ,获得积分10
32秒前
柏林寒冬应助满意的世界采纳,获得10
34秒前
优美的世开完成签到,获得积分10
35秒前
36秒前
37秒前
adam完成签到,获得积分10
37秒前
科研通AI5应助OoO采纳,获得30
38秒前
高分求助中
The Mother of All Tableaux: Order, Equivalence, and Geometry in the Large-scale Structure of Optimality Theory 3000
A new approach to the extrapolation of accelerated life test data 1000
Indomethacinのヒトにおける経皮吸収 400
基于可调谐半导体激光吸收光谱技术泄漏气体检测系统的研究 370
Phylogenetic study of the order Polydesmida (Myriapoda: Diplopoda) 370
Robot-supported joining of reinforcement textiles with one-sided sewing heads 320
Aktuelle Entwicklungen in der linguistischen Forschung 300
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 遗传学 基因 物理化学 催化作用 冶金 细胞生物学 免疫学
热门帖子
关注 科研通微信公众号,转发送积分 3993004
求助须知:如何正确求助?哪些是违规求助? 3533831
关于积分的说明 11263946
捐赠科研通 3273597
什么是DOI,文献DOI怎么找? 1806129
邀请新用户注册赠送积分活动 882968
科研通“疑难数据库(出版商)”最低求助积分说明 809629