医学
动脉瘤
格拉斯哥昏迷指数
闭塞
颈内动脉
蛛网膜下腔出血
死亡率
蛛网膜下腔出血
外科
放射科
作者
Ergün Dağlıoğlu,İlkay Akmangit,Vedat Açık,Fatih Alagöz,Bige Sayın,Özhan Merzuk Uçkun,Deniz Belen,Anıl Arat
标识
DOI:10.5137/1019-5149.jtn.25776-19.2
摘要
To investigate the safety and efficacy of Derivo® embolisation device (DED), a new-generation flow diverter designed to treat cerebrovascular aneurysms, and its long-term clinical outcomes.In total, 146 patients with 182 aneurysms were treated with DED. The mean age of the participants was 51.5 years; among them, 46 (31.5%) presented with acute subarachnoid haemorrhage. The mean aneurysm size was 8.3 mm, and 12 aneurysms were involved the vertebrobasilar system. Ophthalmic aneurysms account for most internal carotid artery (ICA) aneurysms.The Glasgow Coma Scale (GCS) score of 12 patients was < 15. DED was associated with a mortality rate of 2.7% and permanent morbidity rate of 3.4%, and a complete aneurysm occlusion rate was achieved in 78.7% of cases after 7.02 months.The DED device is a new-generation flow diverter with excellent opening behaviour and navigational benefits. Our results indicated a safe aneurysm occlusion with optimum morbidity and mortality values despite the fact that almost one-third of the patients presented with subarachnoid haemorrhage.
科研通智能强力驱动