医学
角膜曲率计
屈光度
光折变性角膜切除术
人工晶状体
激光手术
眼科
激光矫视
白内障手术
折射误差
人工晶状体度数计算
超声乳化术
验光服务
角膜
眼病
视力
作者
Seth Pantanelli,Charles C. Lin,Zaina Al-Mohtaseb,Jennifer Rose‐Nussbaumer,Marcony R. Santhiago,Walter A. Steigleman,Julie M. Schallhorn
出处
期刊:Ophthalmology
[Elsevier]
日期:2021-05-01
卷期号:128 (5): 781-792
被引量:14
标识
DOI:10.1016/j.ophtha.2020.10.031
摘要
PurposeTo review the literature to evaluate the outcomes of intraocular lens (IOL) power calculation in eyes with a history of myopic LASIK or photorefractive keratectomy (PRK).MethodsLiterature searches were conducted in the PubMed database in January 2020. Separate searches relevant to cataract surgery outcomes and corneal refractive surgery returned 1169 and 162 relevant citations, respectively, and the full text of 24 was reviewed. Eleven studies met the inclusion criteria for this assessment; all were assigned a level III rating of evidence by the panel methodologist.ResultsWhen automated keratometry was used with a theoretical formula designed for eyes without previous laser vision correction, the mean prediction error (MPE) was universally positive (hyperopic), the mean absolute errors (MAEs) and median absolute errors (MedAEs) were relatively high (0.72–1.9 diopters [D] and 0.65–1.73 D, respectively), and a low (8%–40%) proportion of eyes were within 0.5 D of target spherical equivalent (SE). Formulas developed specifically for this population requiring both prerefractive surgery keratometry and manifest refraction (i.e., clinical history, corneal bypass, and Feiz-Mannis) produced a proportion of eyes within 0.5 D of target SE between 26% and 44%. Formulas requiring only preoperative keratometry or no history at all had lower MAEs (0.42–0.94 D) and MedAEs (0.30–0.81 D) and higher (30%–68%) proportions within 0.5 D of target SE. Strategies that averaged several methods yielded the lowest reported MedAEs (0.31–0.35 D) and highest (66%–68%) proportions within 0.5 D of target SE. Even after using the best-known methods, refractive outcomes were less accurate in eyes that had previous excimer laser surgery for myopia compared with those that did not have it.ConclusionsCalculation methods requiring both prerefractive surgery keratometry and manifest refraction are no longer considered the gold standard. Refractive outcomes of cataract surgery in eyes that had previous excimer laser surgery are less accurate than in eyes that did not. Patients should be advised of this refractive limitation when considering cataract surgery in the setting of previous corneal refractive surgery. Conclusions are limited by the small sample sizes and retrospective nature of nearly all existing literature in this domain. To review the literature to evaluate the outcomes of intraocular lens (IOL) power calculation in eyes with a history of myopic LASIK or photorefractive keratectomy (PRK). Literature searches were conducted in the PubMed database in January 2020. Separate searches relevant to cataract surgery outcomes and corneal refractive surgery returned 1169 and 162 relevant citations, respectively, and the full text of 24 was reviewed. Eleven studies met the inclusion criteria for this assessment; all were assigned a level III rating of evidence by the panel methodologist. When automated keratometry was used with a theoretical formula designed for eyes without previous laser vision correction, the mean prediction error (MPE) was universally positive (hyperopic), the mean absolute errors (MAEs) and median absolute errors (MedAEs) were relatively high (0.72–1.9 diopters [D] and 0.65–1.73 D, respectively), and a low (8%–40%) proportion of eyes were within 0.5 D of target spherical equivalent (SE). Formulas developed specifically for this population requiring both prerefractive surgery keratometry and manifest refraction (i.e., clinical history, corneal bypass, and Feiz-Mannis) produced a proportion of eyes within 0.5 D of target SE between 26% and 44%. Formulas requiring only preoperative keratometry or no history at all had lower MAEs (0.42–0.94 D) and MedAEs (0.30–0.81 D) and higher (30%–68%) proportions within 0.5 D of target SE. Strategies that averaged several methods yielded the lowest reported MedAEs (0.31–0.35 D) and highest (66%–68%) proportions within 0.5 D of target SE. Even after using the best-known methods, refractive outcomes were less accurate in eyes that had previous excimer laser surgery for myopia compared with those that did not have it. Calculation methods requiring both prerefractive surgery keratometry and manifest refraction are no longer considered the gold standard. Refractive outcomes of cataract surgery in eyes that had previous excimer laser surgery are less accurate than in eyes that did not. Patients should be advised of this refractive limitation when considering cataract surgery in the setting of previous corneal refractive surgery. Conclusions are limited by the small sample sizes and retrospective nature of nearly all existing literature in this domain.
科研通智能强力驱动
Strongly Powered by AbleSci AI