医学
经皮冠状动脉介入治疗
再狭窄
人口
支架
心肌梗塞
外科
靶病变
血管成形术
内科学
气球
临床终点
随机对照试验
心脏病学
环境卫生
作者
Tuomas T. Rissanen,Sanna Uskela,Jaakko Eränen,Pirjo Mäntylä,Annika Olli,Hannu Romppanen,Antti Siljander,Mikko Pietilä,Mikko Minkkinen,Jerry Tervo,Jussi M. Kärkkäinen,Aija Vatanen,Anssi Perälä,Miriam Müller,Pekka Porela,Eeva Palojoki
出处
期刊:The Lancet
[Elsevier BV]
日期:2019-06-13
卷期号:394 (10194): 230-239
被引量:158
标识
DOI:10.1016/s0140-6736(19)31126-2
摘要
Background The optimal technique of percutaneous coronary intervention in patients at high bleeding risk is not known. The hypothesis of the DEBUT trial was that percutaneous coronary intervention with drug-coated balloons is non-inferior to percutaneous coronary intervention with bare-metal stents for this population. Methods The DEBUT trial is a randomised, single-blind non-inferiority trial done at five sites in Finland. Patients were eligible if they had an ischaemic de-novo lesion in a coronary artery or bypass graft that could be treated with drug-coated balloons, at least one risk factor for bleeding, and a reference vessel diameter of 2·5–4·0 mm. Those with myocardial infarction with ST-elevation, bifurcation lesions needing a two-stent technique, in-stent restenosis, and flow-limiting dissection or substantial recoil (>30%) of the target lesion after predilation were excluded. After successful predilation of the target lesion, patients were randomly assigned (1:1), by use of a computer-generated random sequence, to percutaneous coronary intervention with a balloon coated with paclitaxel and iopromide or a bare-metal stent. The primary outcome was major adverse cardiac events at 9 months. Non-inferiority was shown if the absolute risk difference was no more than 3%. All prespecified analyses were done in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT01781546. Findings Between May 22, 2013, and Jan 16, 2017, 220 patients were recruited for the study and 208 patients were assigned to percutaneous coronary intervention with drug-coated balloon (n=102) or bare metal stent (n=106). At 9 months, major adverse cardiac events had occurred in one patient (1%) in the drug-coated balloon group and in 15 patients (14%) in the bare-metal stent group (absolute risk difference −13·2 percentage points [95% CI −6·2 to −21·1], risk ratio 0·07 [95% CI 0·01 to 0·52]; p<0·00001 for non-inferiority and p=0·00034 for superiority). Two definitive stent thrombosis events occurred in the bare metal stent group but no acute vessel closures in the drug-coated balloon group. Interpretations Percutaneous coronary intervention with drug-coated balloon was superior to bare-metal stents in patients at bleeding risk. The drug-coated balloon-only coronary intervention is a novel strategy to treat this difficult patient population. Comparison of this approach to the new generation drug-eluting stents is warranted in the future. Funding B Braun Medical AG, AstraZeneca, and Competitive State Research Funding of the Kuopio University Hospital Catchment Area.
科研通智能强力驱动
Strongly Powered by AbleSci AI