Correlation of Functional Lung Heterogeneity and Dosimetry to Radiation Pneumonitis using Perfusion SPECT/CT and FDG PET/CT Imaging

医学 放射性肺炎 核医学 放射科 剂量学 正电子发射断层摄影术 灌注 放射治疗
作者
Howard J. Lee,Jing Zeng,Hubert Vesselle,Shilpen Patel,Ramesh Rengan,Stephen R. Bowen
出处
期刊:International Journal of Radiation Oncology Biology Physics [Elsevier BV]
卷期号:102 (4): 1255-1264 被引量:25
标识
DOI:10.1016/j.ijrobp.2018.05.051
摘要

Purpose To apply a previously designed framework for predicting radiation pneumonitis by using pretreatment lung function heterogeneity metrics, anatomic dosimetry, and functional lung dosimetry derived from 2 imaging modalities within the same cohort. Methods and Materials Treatment planning computed tomography (CT) scans were co-registered with pretreatment [99mTc] macro-aggregated albumin perfusion single-photon positron emission tomography (SPECT)/CT scans and [18F]-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT scans of 28 patients who underwent definitive thoracic radiation. Clinical radiation pneumonitis was defined as grade ≥2 (Common Terminology Criteria for Adverse Events, v. 4). Anatomic dosimetric parameters (mean lung dose [MLD], volume receiving ≥20 Gy [V20]) were collected from treatment planning scans. Baseline functional lung heterogeneity parameters and functional lung dose-volume parameters were calculated from pretreatment SPECT/CT and FDG PET/CT scans. Functional heterogeneity parameters calculated over the tumor-subtracted lung included skewness, kurtosis, and coefficient of variation from perfusion SPECT and FDG PET and the global lung parenchymal glycolysis and mean standardized uptake value from FDG PET. Functional dose-volume parameters calculated in regions of highly functional lung, defined on perfusion (p) or SUV (s) images, included mean lung dose (pMLD, sMLD) and V20 (pV20, sV20). Fraction of integral lung function receiving ≥20 Gy (pF20, sF20) was also calculated. Equivalent doses in 2 Gy per fraction (EQD2) were calculated to account for differences in treatment regimens and dose fractionation (EQD2Lung). Results Two anatomic dosimetric parameters (MLD, V20) and 4 functional dosimetric parameters (pMLD, pV20, pF20, sF20) were significant predictors of grade ≥2 pneumonitis (area under the curve >0.84; P < .05). Dose-independent functional lung heterogeneity metrics were not associated with pneumonitis incidence. At thresholds of 100% sensitivity and 65% to 91% specificity, corresponding to maximum prediction accuracy for pneumonitis, these parameters had the following cutoff values: MLD = 13.6 Gy EQD2Lung, V20 = 25%, pMLD = 13.2 Gy EQD2Lung, pV20 = 15%, pF20 = 17%, and sF20 = 25%. Significant parameters MLD, V20, pF20, and sF20 were not cross-correlated to significant parameters pMLD and pV20, indicating that they may offer independently predictive information (Spearman ρ < 0.7). Conclusions We reported differences in anatomic and functional lung dosimetry between patients with and without pneumonitis in this limited patient cohort. Adding selected independent functional lung parameters may risk stratify patients for pneumonitis. Validation studies are ongoing in a prospective functional lung avoidance trial at our institution. To apply a previously designed framework for predicting radiation pneumonitis by using pretreatment lung function heterogeneity metrics, anatomic dosimetry, and functional lung dosimetry derived from 2 imaging modalities within the same cohort. Treatment planning computed tomography (CT) scans were co-registered with pretreatment [99mTc] macro-aggregated albumin perfusion single-photon positron emission tomography (SPECT)/CT scans and [18F]-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT scans of 28 patients who underwent definitive thoracic radiation. Clinical radiation pneumonitis was defined as grade ≥2 (Common Terminology Criteria for Adverse Events, v. 4). Anatomic dosimetric parameters (mean lung dose [MLD], volume receiving ≥20 Gy [V20]) were collected from treatment planning scans. Baseline functional lung heterogeneity parameters and functional lung dose-volume parameters were calculated from pretreatment SPECT/CT and FDG PET/CT scans. Functional heterogeneity parameters calculated over the tumor-subtracted lung included skewness, kurtosis, and coefficient of variation from perfusion SPECT and FDG PET and the global lung parenchymal glycolysis and mean standardized uptake value from FDG PET. Functional dose-volume parameters calculated in regions of highly functional lung, defined on perfusion (p) or SUV (s) images, included mean lung dose (pMLD, sMLD) and V20 (pV20, sV20). Fraction of integral lung function receiving ≥20 Gy (pF20, sF20) was also calculated. Equivalent doses in 2 Gy per fraction (EQD2) were calculated to account for differences in treatment regimens and dose fractionation (EQD2Lung). Two anatomic dosimetric parameters (MLD, V20) and 4 functional dosimetric parameters (pMLD, pV20, pF20, sF20) were significant predictors of grade ≥2 pneumonitis (area under the curve >0.84; P < .05). Dose-independent functional lung heterogeneity metrics were not associated with pneumonitis incidence. At thresholds of 100% sensitivity and 65% to 91% specificity, corresponding to maximum prediction accuracy for pneumonitis, these parameters had the following cutoff values: MLD = 13.6 Gy EQD2Lung, V20 = 25%, pMLD = 13.2 Gy EQD2Lung, pV20 = 15%, pF20 = 17%, and sF20 = 25%. Significant parameters MLD, V20, pF20, and sF20 were not cross-correlated to significant parameters pMLD and pV20, indicating that they may offer independently predictive information (Spearman ρ < 0.7). We reported differences in anatomic and functional lung dosimetry between patients with and without pneumonitis in this limited patient cohort. Adding selected independent functional lung parameters may risk stratify patients for pneumonitis. Validation studies are ongoing in a prospective functional lung avoidance trial at our institution.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
DW发布了新的文献求助10
刚刚
1秒前
2秒前
QQWRV完成签到,获得积分10
2秒前
3秒前
3秒前
yz完成签到,获得积分10
3秒前
angela发布了新的文献求助10
4秒前
桐桐应助Quincy采纳,获得10
4秒前
呆呆棵发布了新的文献求助10
5秒前
汉堡包应助Cliu1981采纳,获得10
5秒前
5秒前
打打应助蟹老板采纳,获得10
5秒前
QQWRV发布了新的文献求助10
7秒前
魏无招完成签到 ,获得积分10
7秒前
7秒前
风趣可愁发布了新的文献求助10
7秒前
小羊皮革完成签到,获得积分10
8秒前
852应助你嵙这个期刊没买采纳,获得10
9秒前
9秒前
9秒前
baowenquan完成签到 ,获得积分10
9秒前
9秒前
9秒前
9秒前
9秒前
大个应助淡定的乐安采纳,获得10
10秒前
自信的秀发完成签到 ,获得积分10
10秒前
安可0812发布了新的文献求助10
10秒前
呆呆棵完成签到,获得积分10
11秒前
小羊皮革发布了新的文献求助10
11秒前
ding应助成就的靖琪采纳,获得10
11秒前
12秒前
完美世界应助AOYU采纳,获得10
12秒前
传奇3应助小肥采纳,获得10
12秒前
李健的小迷弟应助石榴采纳,获得10
13秒前
Baneyhua发布了新的文献求助10
13秒前
ddz发布了新的文献求助10
14秒前
haha发布了新的文献求助10
14秒前
其7完成签到,获得积分10
15秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
The Organometallic Chemistry of the Transition Metals 800
Chemistry and Physics of Carbon Volume 18 800
The Organometallic Chemistry of the Transition Metals 800
Leading Academic-Practice Partnerships in Nursing and Healthcare: A Paradigm for Change 800
The formation of Australian attitudes towards China, 1918-1941 640
Signals, Systems, and Signal Processing 610
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 工程类 有机化学 化学工程 生物化学 计算机科学 物理 内科学 复合材料 催化作用 物理化学 光电子学 电极 细胞生物学 基因 无机化学
热门帖子
关注 科研通微信公众号,转发送积分 6437584
求助须知:如何正确求助?哪些是违规求助? 8252010
关于积分的说明 17558044
捐赠科研通 5496007
什么是DOI,文献DOI怎么找? 2898612
邀请新用户注册赠送积分活动 1875316
关于科研通互助平台的介绍 1716340