摘要
Indoor AirVolume 14, Issue s7 p. 195-201 HVAC—the importance of clean intake section and dry air filter in cold climate S. O. Hanssen, S. O. Hanssen Department of Energy and Process Technology, Norwegian University of Science and Technology, Trondheim, NorwaySearch for more papers by this author S. O. Hanssen, S. O. Hanssen Department of Energy and Process Technology, Norwegian University of Science and Technology, Trondheim, NorwaySearch for more papers by this author First published: 25 August 2004 https://doi.org/10.1111/j.1600-0668.2004.00288.xCitations: 8 Professor Sten Olaf Hanssen Department of Energy and Process Engineering, Faculty of Engineering Science and Technology, Norwegian University of Science and Technology, N-7491 Trondheim, Norway, e-mail: [email protected] Read the full textAboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL References Ahlén, C. (1995) ' Determination of viable microbes in indoor air – what do we gain?'. Proceedings of International Symposium on Indoor Air Quality in Practice – Moisture and Cold Climate Solutions, 255– 259 . Ahlén, C. and Haugen, E.N. (1996) "HVAC-induced alterations in microbial flora of indoor air – a potential for increased pathogenicity of microbes?'. In: Proceedings of Indoor Air '96, Nagoya, Japan, 3, 645– 649. Ahlén, C., Haugen, E.N., Frydenlund, F. et al. (1999) "Composting in ventilation filters – a possible key to altered thermotolerance in microbial flora of indoor air'. Proceedings of Indoor Air ′99, Edinburgh, 2, pp. 184– 189. ANSI/ASHRAE (2001) "Standard 62-2001: 'Ventilation for Acceptable Indoor Air Quality', Atlanta, GA, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. ASHRAE (1996) "Building Maintenance Linked to Indoor Air Quality Problems', ASHRAE Journal, April. CEN (2002). Working Draft prE.N., 13779, CEN/TC156/WG7-N 97: Ventilation for non-residential buildings – Performance requirements for ventilation and room-conditioning systems. Brussels: European Committee for Standardisation. CEN (2003) Final Draft, prE.N. 13779 October 2003 ICS 91.140.30: Ventilation for Non-Residential Buildings – Performance Requirements for Ventilation and Room-Conditioning Systems', Ref. PrEN, 13779:2003 E. Brussels: European Committee for Standardisation. CEN ENV (1997) 12097:1997 E Ventilation for buildings – Ductwork – Requirements for ductwork components to facilitate maintenance of ductwork systems', European prestandard. DIN (1946) Part 2, 'Heating, ventilation and air conditioning, Requirements relating to health', January 1994 . ECA (2000) "European Collaborative Action Indoor Air Quality and its Impact on Man", 'Risk Assessment in Relation to Indoor Air Quality' Report no. 22 (EUR 19529/EN), European Commission Joint Research Centre. Environmental Institute, Ispra, Italy. Luxembourg: Office for Publications of the European Communities. Frydenlund, F., Haugen, E.N., Ahlén, C., Bryn, I.M., Hanssen, S.O. and Mogedal, G.T. (2002) "Macro- and Microevaluation of Air Intake – A Demonstration of the need for more Optimal Tools", Proceedings of the 9th International Conference on Indoor Air 1, 362– 367. Hanssen, S.O (2000) "Quality Assurance for IAQ in the Construction Process", Plenary State of the Art Lecture at the International Conference: 'Healthy Buildings 2000', Espoo, Helsinki, Finland, Abstract no: r00015843. ISIAQ (1996) "ISIAQ Guideline TFI.-1996: 'Control of moisture problems affecting biological indoor air quality', International Society of Indoor air Quality and Climate. Kotzias, D, European Collaborative Action (ECA), European Commission, Urban Air, Indoor Environment and Human Exposure (formerly 'Indoor Air Quality & its Impact on Man') (2000) "Future Needs for Policy–Science Interface in the EU' In: Proceedings from Workshop at Makedonia Palace, Thessaloniki, Greece (eds S. Kephalopoullos, M. Jantunen and D Kotzias). Lindvall, T, Abel, E, Anderson, J et al. (2002) The Healthy Building – for the Benefit of the European People', Application Form, Expressions of Interest to Identify Research Actions as a Basis for the Preparation of Work Programmes for the 6th Framework Programme for Research. Stockholm: Institute of Environmental Medicine, Karolinska Institute. Melding HO-1/98, National Office of Building Technology and Administration, Norway: Technical Regulations under the Planning and Building Act (1997, 22 January 1997) No. 33: Regulations concerning requirements for construction works and products for construction works, http://www.bebygg.no/beweb/english/englishinfo.htm. National Building Code of Finland, D2 (1987) "Indoor Climate and Ventilation of Buildings', Ministry of the Environment", Regulation and Guidelines. Ressem, S., Toenseth, S., (1996) 'Nice microbes can make you sick', GEMINI, - Research news from, NTNU. and the SINTEF Group no. 4. Trondheim, Norway. GEMINI on Internet: http://www.sintef.no.gemini. Citing Literature Volume14, Issues7August 2004Pages 195-201 ReferencesRelatedInformation