医学
Oswestry残疾指数
射线照相术
笼子
腰椎
外科
骨科手术
椎板切除术
脊柱疾病
脊柱融合术
椎管狭窄
背痛
放射性武器
柯布角
回顾性队列研究
植入
腰痛
可视模拟标度
矢状面
固定(群体遗传学)
椎间盘切除术
脊髓
替代医学
病理
精神科
组合数学
数学
作者
Chen Bingqian,Xue Feng,Shen Xiaowen,Zhang Feng,Fang Xiaowen,Qian Yufeng,Dong Qi-rong
标识
DOI:10.1186/s13018-015-0243-3
摘要
The traditional posterior lumbar interbody fusion (PLIF) technique usually involves implantation of two cages through a bilateral approach and bilateral laminectomy, which requires bilateral transpedicle screw fixation. The procedure itself has several negative impacts. Therefore, a modified PLIF procedure that includes insertion of a unilateral cage through the symptomatic side with supplementary unilateral pedicle screws has been conducted.Thirty-one patients with unilateral radiculopathy who were diagnosed with spinal stenosis along with degenerative disc disease and a herniated intervertebral disc with lumbar instability underwent a unilateral PLIF using a single cage and unilateral pedicle screws. The postoperative clinical evaluation was based on the visual analogue scale (VAS) and the Oswestry Disability Index (ODI) for back pain and leg pain at multiple time points following the surgery. Radiological assessments were performed with lateral plain radiographs taken preoperation, immediately postoperation, 1, 2, 3 and 6 months postoperation and at the most recent follow-up.The patients all underwent a single-level fusion, and the mean duration for the surgeries was 94 min. The mean haemorrhage volume was 250 ml, and no blood transfusion was required for any of the cases. Twelve months postoperatively, all patients had achieved an Excellent or Good outcome (Excellent in 28 patients and Good in 3). The mean pain score was 6.8 prior to surgery and decreased to 2.3 at the 3-month postoperative examination. No significant complications or neurological deterioration occurred. None of the 31 patients appeared to have any fusion failure. No broken screw, screw loosening, significant cage migration or subsidence was observed in any of the cases. A mean increase in the intervertebral disc height of 3.14 mm from the preoperative measurement to the most recent follow-up examination was determined to be statistically significant (p = 0.05).Conducting PLIF using the diagonal insertion of a single cage with supplemental unilateral transpedicular screw instrumentation enables sufficient decompression and solid interbody fusion to be achieved with minimal invasion of the posterior spinal elements. This technique is a more clinically secure, straightforward and cost-effective way to perform PLIF.
科研通智能强力驱动
Strongly Powered by AbleSci AI